9 Faults
9.1 Faults ThunderION
Table 4, faults when connected to a 24 V DC power supply
Signaling
Problem
Green
No/poor ionisation
However high voltage
Continuous
on emitters
HVOK active
(can be checked with
(external)
a high voltage meter/
Tension)
No LED
No high voltage on
emitters.
HVOK not
active
(external)
Green flashing
No high voltage on
HVOK not
emitters.
active
(external)
Red
(lower) High voltage
Continuous
on emitters
HVOK not
active
(external)
Red
Internal hardware
flashing
error
ThunderION2ThunderIONIQ2_UM_9752160050_NL_D_GB_F_V2_2
Cause
Anti-static bar is fouled.
Emitters are damaged.
Emitters are covered.
Position of neutralizing not OK Change position
Cable, connectors or power
supply not connected
Bar faulty.
"Remote operation" input is
not controlled
Bar placed too close to
conductive parts
Bar is extremely fouled.
Bar faulty.
Supply voltage too low
Internal Temp too high
HV OK overload
Remedy
Clean anti-static bar.
Replace emitters.
Remove the cover.
Restore supply voltage
Return anti-static bar
Set Remote to On
(5.6.2)
Move anti-static bar.
Clean anti-static bar.
Return anti-static bar.
Check power supply
and length of the cable
Tamb> 55C or anti-
static bar faulty
Reduce load
84

Publicité

loading

Ce manuel est également adapté pour:

Thunderion iq 2.0