PROCESS
Black-out
SETPOINT
Step 2
Step 1
9.4.2 Recovery with programmable recovery gradient
To enable cycle recovery with a recovery gradient, enter on parameter 22 r.i.cy.
a value (degrees/hour if temperature) greater than 1. At restarting if the kiln
temperature (process) is lower than the setpoint, ATR902 locks the working cycle
executing a step with the rising gradient set on parameter 22 r.i.cy. to return to
the setpoint value entered before the power failure and the cycle restarts form
that point. In recovery mode the point on the right of the red display flashes and
display shows rec instead of the cycle number.
PROCESS
Black-out
SETPOINT
Step 2
Step 1
Step 3
Step 2
Time
Step 3
Step 2
Recovery step with
programmable
gradient (Par. 22)
NB: After a power-off the chronometer
will restart from 00:00.
Recovery will start only for holding or
rising steps.
To exit manually from recovery mode
press
Time
or
.
User manual - ATR902 - 17