FLEXLINE ELECTRONIC PIN LOCK — INSTRUCTIONS FOR USE
4.
Type the new user code and press ENTER.
5.
Retype the new user code and press ENTER.
6.
If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
NOTE: Self Lock RegulatoR operates with a fixed code. Changing the Supervisor Code
To change the supervisor code, refer "RegulatoR Programming Mode" to enter programming mode.
The factory default supervisor code is 12345 (supervisor codes must be 4 to 8 digits in length.)
NOTE: There is a 10 second programming time limit between each step. If RegulatoR times out or an error is made, programming will
end and you will need to enter programming mode again.
1.
Place RegulatoR into programming mode (See "RegulatoR Programming Mode").
2.
Press "2" and then press ENTER.
3.
Type the current supervisor code and press ENTER.
4.
Type the new supervisor code and press ENTER.
5.
Retype the new supervisor code and press ENTER.
6.
If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
Reset Instructions
RegulatoR
features a reset code which will restore the default supervisor code and user code. RegulatoR was shipped with reset
®
stickers; one attached to the back of the RegulatoR and an extra sticker that should be saved in a safe and secure location for future
reference.
NOTE: To restore the factory default supervisor and user code, type the "Reset Code" assigned to the RegulatoR and press ENTER.
Programming Security Timeout ON / Security Timeout OFF
WARNING: Security Timeout ON will disable the RegulatoR from use for 5 minutes when 5 invalid attempts to unlock RegulatoR occur.
During this time, RegulatoR will not unlock with either the valid user or supervisor code.
To change the RegulatoR to Security Timeout ON or OFF, refer "RegulatoR Programming Mode" to enter programming mode.
NOTE: There is a 10 second programming time limit between each step. If RegulatoR times out or an error is made, programming will
end and you will need to enter programming mode again.
1.
Place RegulatoR into programming mode (See "RegulatoR Programming Mode").
2.
To turn Security Timeout ON, type "11" and then press ENTER.
OR
1.
To turn Security Timeout OFF, type "10" and then press ENTER.
2.
If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
Reset User Code to Factory Default 1234
To reset the User Code to the factory default 1234, refer "RegulatoR Programming Mode" to enter programming mode.
NOTE: There is a 10 second programming time limit between each step. If RegulatoR times out or an error is made, programming will
end and you will need to enter programming mode again.
1.
Place RegulatoR into programming mode (See "RegulatoR Programming Mode").
2.
Type "8888" and then press the ENTER button.
3.
If successful, the green indicator light will illuminate for 1 second.
Continue programming or press 9 and then ENTER to exit programming.
4
www.metro.com
L01-655
REV 01/20