Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Programming – Introduction
CompX
RegulatoR
is easy to program and operate.
®
®
Type the user code (factory default 1234) and press ENTER, then rotate the knob clockwise to unlock the cart.
The supervisor can change operating codes, modes and restore lock settings.
While RegulatoR is easy to program, we highly recommend reading the complete programming instructions
prior to making any changes. Remember to keep track of any programming changes.
Button locations, indicator lights and knob referenced in the programming instructions are shown below:
Indicator Lights
Green - Indicates button
input and valid code
Yellow - Indicates low battery
or program mode
Red - Indicates incorrect
entry
Follow the directions below to operate (unlock and lock) the standard Self Lock version of RegulatoR:
Type a valid code, press ENTER,
Rotate knob clockwise,
Release knob, RegulatoR knob will return to the locking position.
IMPORTANT: The Flexline cart is not secure until the red locking handle is pushed down to relock the cart !
RegulatoR Programming Mode
To enter programming mode you must know the supervisor code. The default supervisor code is 12345.
Once in programming mode, multiple changes can be made prior to exiting programming.
NOTE: There is a 10 second programming time limit between each step. If RegulatoR times out or an error is made, programming will
end and you will need to enter programming mode again.
1.
Lock must be in the locked position prior to entering programming mode.
2.
Type supervisor code and press ENTER.
3.
Rotate the knob to the unlocked position and press and hold ENTER for "3 seconds" (yellow indicator light will illuminate).
4.
You can now let go of the knob.
5.
With the yellow indicator light illuminated, programming can begin.
Changing the User Code
To change the user code, refer to "RegulatoR Programming Mode" to enter programming mode.
The factory default user code is 1234 (User codes must be 4 to 8 digits in length.)
NOTE: There is a 10 second programming time limit between each step. If RegulatoR times out or an error is made, programming will
end and you will need to enter programming mode again.
1.
Place RegulatoR into programming mode (See "RegulatoR Programming Mode").
2.
Press "1" and then press ENTER.
3.
Type the current user code and press ENTER.
FLEXLINE ELECTRONIC PIN LOCK — INSTRUCTIONS FOR USE
CLEAR button - erases any key input
ENTER button - is used to complete code
entry or begin programming
3
www.metro.com
made in error
KNOB - Rotate clockwise to unlock and
counter clockwise to allow relock
L01-655
REV 01/20

Publicité

loading