SECTION 6
Finishing the Installation
1.
Install the appropriate filters.
Charcoal Filters: If the range hood will be run ductless, remove and discard the grease
filters that were included with the unit and install model BCCF-02 charcoal filters
instead.
Grease Filters: If the range hood will be vented to the exterior of the home, install the
grease filters supplied with the hood by sliding tab at rear of filter into slot in hood.
While holding in handle of filter, lift filter into place and release handle. the filter should
snap securely into place (Figure 10).
Figure 10
2.
Remove any protective plastic adhered to the range hood.
3.
Turn switches to the OFF ( • ) position and restore power. Test that the light and the fan
are operating properly.
4.
If there is any vibration noise, check for the source and try to tighten fasteners or adjust
the tape to make a tighter connection or seal.
SECTION 7
Operation
Controls
Your Range Hood is equipped with two rotary switches with one controlling the lighting and
the other controlling the exhaust fan blower. The light switch has three positions, High, Low,
and Off. The fan switch has four positions, Off, High, Medium, and Low (Figure 11).
Figure 11
Trouble
1. Hood does not operate when the switch is on.
2. Hood is operating, but air moves slower than normal.
3. Hood is making a rattling noise.
Installer:
Place of Purchase:
6728027 Rev. O 1-16
SECTION 8
Maintenance
Grease Filters
Included with your range hood are aluminum grease filters that should be washed at least once
a month. The filters are dishwasher safe and should be washed in a mild soap or detergent.
Refer to Step 3 of Section 1 Preparing the Range Hood, to remove filters. If the grease filters
become damaged, replace with Air King Model BCGF-01 Grease Filter.
Charcoal Odor Filter
If you have installed the optional charcoal odor filters, they cannot be washed and must be
discarded and replaced when they become noticeably dirty, have stopped filtering the odors, or
at least once per year. Replace with Air King Model BCCF-02 Odor Filters.
Changing the Lamp
Remove the lamp cover on the underside of the hood. Remove lamp by gently twisting the lamp
base counterclockwise while applying outward pressure. Installation is the reverse of removal.
Replace with Air King model 26SBL or a compatible GU24 26 watt self ballasted lamp.
Filter
Night Light: Unscrew night light bulb from socket and replace with a 4 watt maximum type
C7 (candelabra base) night light bulb.
Fuse
To replace the fuse, turn the fuse cap located next to the wire connector counter clockwise
and pull out. Replace with a Bussman MDA 125-Volt, 1.5 Amp Max. fuse (models VAL30AB and
VAL36AB utilize a 3 Amp Max fuse). Reinstall the fuse back into the hood.
Cleaning
1.
2.
CALIFORNIA RESIDENTS ONLY:
Troubleshooting Guide
Probable Cause
1a.
A fuse may be blown or a circuit tripped.
1b.
Wiring is not connected properly.
2.
Obstruction in the exhaust ducting.
3a.
Filters are loose.
3b.
Duct connection is loose.
www.airkinglimited.com
CAUTION:
SERVICE PANEL BEFORE SERVICING THE UNIT.
CAUTION:
DO NOT USE GASOLINE, BENZINE, THINNER, HARSH
CLEANSERS, ETC., AS THEY MAY DAMAGE THE RANGE HOOD.
Clean your range hood with a mild detergent, such as dishwashing liquid, and dry with a soft
cloth. NEVER USE ANY ABRASIVE PADS OR SCOURING POWDERS. Completely dry before
restoring power. NEVER IMMERSE ELECTRICAL PARTS IN WATER.
The fan assembly can be vacuumed when build up (dirt, lint, etc.) accumulates over time.
The fan is permanently lubricated and does not require oiling.
WARNING:
THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR
CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER.
WARNING:
THIS PRODUCT CAN EXPOSE YOU TO A CHEMICAL [OR
CHEMICALS] KNOWN TO THE STATE OF CALIFORNIA TO CAUSE REPRODUCTIVE
TOXICITY.
Suggested Remedy
1a.
Replace fuse or reset circuit breaker.
1b.
Turn off power to unit. Check that all wires are connected.
2.
Check for any obstructions in the ducting including filter.
3a.
Turn off power to unit. Check that all filter are securely in place.
3b.
Turn off power to unit. Check that duct connection is tight.
Installation Date:
Model Number:
MAKE SURE POWER IS SWITCHED OFF AT