Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
AX Series
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
When using electrical appliances, basic precautions should always be followed to
reduce the risk of fire, electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you have
questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK AND
INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified person(s) in
accordance with all applicable codes and standards, including fire-related
construction.
b) Sufficient air is needed for proper combustion and exhausting of gases through
the flue (chimney) of fuel burning equipment to prevent back drafting. Follow
the heating equipment manufacturer's guideline and safety standards such
as those published by the National Fire Protection Association (NFPA) and the
American Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
c) When cutting or drilling into wall or ceiling, do not damage electrical wiring and
other hidden utilities.
CAUTION:
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO
EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
CAUTION:
TO REDUCE THE RISK OF FIRE AND TO PROPERLY EXHAUST
AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT VENT EXHAUST AIR INTO
SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL SPACES, OR
GARAGES.
d) Ducted fans must always be vented to the outdoors.
e) This unit must be grounded.
f)
To avoid motor bearing damage and noisy and/or unbalanced impellers, keep
drywall spray, construction dust, etc. off power unit.
g) Read all instructions before installing or using range hood.
6728008 Rev. B 3-13
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
SAVE THESE INSTRUCTIONS
WARNING:
USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE.
WARNING: TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on low or
medium settings.
b) Always turn hood ON when cooking at high heat or when flambéing food
(ie. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed to
accumulate on fan filter.
d) Use proper pan size. Always use cookware appropriate for the size of the
surface element.
WARNING:
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then
turn off burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out
immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - You may be burned.
c) DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d) Use an extinguisher ONLY if:
I.
II.
III.
IV.
WARNING:
DUCTWORK.
www.airkinglimited.com
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, DO NOT
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
You know you have a Class ABC extinguisher, and you already know
how to operate it.
The fire is small and contained in the area where it started.
The fire department is being called.
You can fight the fire with your back to an exit.
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
Range Hood
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing AX Serie

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL AX Series Range Hood READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    SECTION 3 INSTALLATION INSTRUCTIONS Prepare the Hood for Installation CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE Choose the type of ducting you will require. This model is equipped to vent either Vertically STARTING INSTALLATION. or Horizontally through a 3-1/4" x 10" duct. It can be modified to vent through a 7" round duct with the addition of a model E-22a or RDC7 Duct Collar (not included) (Figure 3).
  • Page 3 NOTE: DO NOT disconnect any wiring that has already been crimped with a wire connector Hood from the factory. Body Install the wire compartment cover and tighten screw. Make sure all wiring is securely E-22A/RCD7 contained within the wire compartment. Damper SECTION 6 Ducting...
  • Page 4: Troubleshooting Guide

    SECTION 9 Maintenance CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE SERVICING THE UNIT. Filters Grease Filter - Included with your range hood is an aluminum grease filter that should be washed in hot water with detergent once a month. Reverse the instructions in the “Finishing the Installation”...
  • Page 5: Customer Service

    LIMITED WARRANTY WHAT THIS WARRANTY COVERS: This product is warranted against defects in workmanship and/or materials. HOW LONG THIS WARRANTY LASTS: This warranty extends only to the original purchaser of the product and lasts for one (1) year from the date of original purchase or until the original purchaser of the product sells or transfers the product, whichever first occurs.
  • Page 6: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM Qty. Description Replacement Part # Filter RF35 5S4199011 Light Lens 5S4199004 Wire Compartment Cover 5S4199005 Lamp Holder 5S4199006 Jumper Wire 5S4199007 Switch Plate with Switches - White 5S1107183 Black 5S1107188 Motor Assembly 5S1148001 Damper Assembly 5S1199080 www.airkinglimited.com 6728008 Rev.
  • Page 7: Hotte De Cuisinière

    INSTRUCCIONES IMPORTANTES – MANUAL DE OPERACIÓN AX Series Hotte de cuisinière LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORM- ER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 SECTION 3 INSTRUCTIONS D’INSTALLATION Préparez la hotte pour l’installation MISE EN GARDE : ASSUREZ-VOUS QUE L’ALIMENTATION ÉLECTRIQUE Choisir le type de conduits qui sera requis. Ce modèle est équipé pour souffler tant EST COUPÉE À PARTIR DU PANNEAU DE DISTRIBUTION AVANT DE COMMENCER verticalement qu’horizontalement dans un conduit de 8,25 x 25,4 cm (3-1/4 po x 10 po).
  • Page 9 REMARQUE : NE PAS déconnecter quelque fil qui ait déjà été serti avec un connecteur de fil Hood à l’usine. Body Placez le couvercle du compartiment de fils et serrez la vis. Assurez-vous que tous les E-22A/RCD7 fils sont placés de manière sécuritaire à l’intérieur du compartiment. Damper SECTION 6 Conduits...
  • Page 10: Entretien

    SECTION 9 Entretien MISE EN GARDE : ASSUREZ-VOUS QUE L’ALIMENTATION ÉLECTRIQUE EST COUPÉE À PARTIR DU PANNEAU DE DISTRIBUTION AVANT DE COMMENCER L’INSTALLATION. Filtres Filtre à graisses – Un filtre à graisses en aluminium est inclus avec votre hotte et il devrait être nettoyé...
  • Page 11: Garantie Limitée

    GARANTIE LIMITÉE CE QUE COUVRE CETTE GARANTIE : Ce produit est garanti contre tout vice de fabrication ou de matière. COMBIEN DE TEMPS CETTE GARANTIE DURE : Cette garantie se rapporte seulement à l'acheteur original du produit et dure pendant une (1) année de la date de l'achat original ou jusqu'à...
  • Page 12: Diagramme Des Pièces De Remplacement

    DIAGRAMME DES PIÈCES DE REMPLACEMENT # de pièce Qte. Description de remplacement Filtre RF35 5S4199011 Lentille de lumière 5S4199004 Couvercle de compartiment à câblage 5S4199005 Support à lampe 5S4199006 Cavalier 5S4199007 Plaque d’interrupteur avec des interrupteurs 5S1148001 Blanc 5S1107183 Noir 5S1107188 Assemblement de Moteur 5S1107103...

Table des Matières