Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
Models: ESSEV28, ESSEV30
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN
THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
When using electrical appliances, basic precautions should always
be followed to reduce the risk of fire, electric shock and injury to
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON, OBSERVE THE
FOLLOWING:
a)
Use this unit only in the manner intended by the manufacturer.If you have questions,
contact the manufacturer.
b)
Before servicing or cleaning the unit, switch power off at service panel and lock the
service disconnecting means to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked, securely fasten a prominent
warning device, such as a tag, to the service panel.
WARNING:
ELECTRIC SHOCK AND INJURY TO PERSON, OBSERVE THE
FOLLOWING:
a)
Installation work and electrical wiring must be done by qualified person(s) in accordance
with all applicable codes and standards, including fire-related construction.
b)
Sufficient air is needed for proper combustion and exhausting of gases through the
flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating
equipment manufacturer's guideline and safety standards such as those published by
the National Fire Protection Association (NFPA) and the American Society for Heating,
Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities.
c)
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other
hidden utilities.
CAUTION:
USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
CAUTION:
PROPERLY EXHAUST AIR, BE SURE TO DUCT AIR OUTSIDE - DO NOT
VENT EXHAUST AIR INTO SPACES WITHIN WALLS OR CEILINGS OR INTO ATTICS, CRAWL
SPACES, OR GARAGES.
d)
Ducted fans must always be vented to the outdoors.
e)
This unit must be grounded.
f)
To avoid motor bearing damage and noisy and/or unbalanced impellers, keep drywall
spray, construction dust, etc. off power unit.
g)
Read all instructions before installing or using range hood.
WARNING:
SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED
CONTROL DEVICE.
6728028 Rev. L 12-15
OPERATING MANUAL
AND/OR PROPERTY DAMAGE!
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
GENERAL SAFETY INFORMATION
person, including the following:
TO REDUCE THE RISK OF FIRE,
TO REDUCE THE RISK OF FIRE,
FOR GENERAL VENTILATING USE ONLY. DO NOT
TO REDUCE THE RISK OF FIRE AND TO
TO REDUCE THE RISK OF FIRE, ELECTRIC
SAVE THESE INSTRUCTIONS
WARNING:
GREASE FIRE:
a)
Never leave surface units unattended at high settings. Boil overs cause smoking
and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b)
Always turn hood ON when cooking at high heat or when flambéing food (ie. Crepes
Suzette, Cherries Jubilee, Peppercorn Beef Flambé).
c)
Clean ventilating fans frequently. Grease should not be allowed to accumulate on
fan filter.
d)
Use proper pan size. Always use cookware appropriate for the size of the surface
element.
WARNING:
IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:
a)
SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off
burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
b)
NEVER PICK UP A FLAMING PAN - You may be burned.
c)
DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result.
d)
Use an extinguisher ONLY if:
I.
You know you have a Class ABC extinguisher, and you already know how to
operate it.
II.
The fire is small and contained in the area where it started.
III.
The fire department is being called.
IV.
You can fight the fire with your back to an exit.
WARNING:
METAL DUCTWORK.
WARNING:
THE BUILDING HAS A STRONG EFFECT ON THE AIR FLOW, NOISE AND ENERGY
USE OF THE FAN. USE THE SHORTEST, STRAIGHTEST DUCT ROUTING POSSIBLE FOR
BEST PERFORMANCE, AND AVOID INSTALLING THE FAN WITH SMALLER DUCTS THAN
RECOMMENDED. INSULATION AROUND THE DUCTS CAN REDUCE ENERGY LOSS AND
INHIBIT MOLD GROWTH. FANS INSTALLED WITH EXISTING DUCTS MAY NOT ACHIEVE
THEIR RATED AIRFLOW.
www.airkinglimited.com
Power Unit
TO REDUCE THE RISK OF A RANGE TOP
TO REDUCE THE RISK OF INJURY TO PERSONS
TO REDUCE THE RISK OF FIRE, USE ONLY
THE DUCTING FROM THIS FAN TO THE OUTSIDE OF
1 of 12

Publicité

Table des Matières
loading

Sommaire des Matières pour AirKing ESSEV28

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Power Unit Models: ESSEV28, ESSEV30 READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2: Installation Instructions

    (Figure 1): Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed ESSEV28 models: 26-7/8" wide by 10" deep. with existing ducts may not achieve their rated air flow. ESSEV30 models: 30" wide by 10" deep...
  • Page 3 SECTION 6 Wiring CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. Figure 7 Examine the wire compartment cover and select the most convenient wire entrance and remove the knock out.
  • Page 4: Troubleshooting Guide

    Troubleshooting Guide Trouble Probable Cause Suggested Remedy 1. Hood does not operate when the switch is on. A fuse may be blown or a circuit tripped. Replace fuse or reset circuit breaker. Wiring is not connected properly. Turn off power to unit. Check that all wires are connected. 2.
  • Page 5: Replacement Parts Diagram

    REPLACEMENT PARTS DIAGRAM Qty. Description Replacement Part # Collar Assembly 5S5299100 Blower Plate 5S1137002 Wire Compartment 5S1137003 Incoming Power Harness 5S9199703 Blower Assembly 5S1140018 Fan Switch 5S1144085 Light Switch 5S4199018 Switch Plate 5S1142010 Knob 5S1142011 GU24 Lamp Holder 5S9199701 18 watt GU24 Bulb 5S1999718 Lens Cover 5S1112011...
  • Page 6 NOTES 6728028 Rev. L 12-15 www.airkinglimited.com 6 of 12...
  • Page 7: Unité De Puissance

    INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Unité de puissance Modèles: ESSEV28, ESSEV30 LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 8 Il se peut que les cabinet ou le panneau où l'unité d’alimentation sera montée (Figure 1): ventilateurs installés avec des conduits existants n’atteignent pas leur débit d’air nominal. Modèles ESSEV28 : 26.88 po x 10 po de profondeur AVERTISSEMENT : POUR RÉDUIRE LES RISQUES Modèles ESSEV30 : 30 po x 10 po de profondeur...
  • Page 9: Alimentation De La Résidence

    SECTION 6 Câblage AVERTISSEMENT : TOUTES LES CONNEXIONS ÉLECTRIQUES DOIVENT ÊTRE FAITES EN CONFORMITÉ AVEC LES CODES LOCAUX, LES ORDONNANCES OU LE CODE ÉLECTRIQUE NATIONAL. SI VOUS N’ÊTES PAS FAMILIER AVEC LES MÉTHODES D’INSTALLATION DE CÂBLAGE ÉLECTRIQUE, RECOURREZ Figure 7 AUX SERVICES D’UN ÉLECTRICIEN QUALIFIÉ.
  • Page 10: Guide De Dépannage

    Guide de dépannage Trouble Cause possible Solution suggérée 1. La hotte ne fonctionne pas lorsque 1a. Un fusible peut être grillé ou un disjoncteur peut être déclenché. 1a. Remplacer le fusible ou réinitialiser le disjoncteur. l’interrupteur est à EN (ON). 1b.
  • Page 11 TABLEAU DES PIÈCES DE RECHANGE # de pièce de Qté. Description remplacement Assemblement de collier 5S5299100 Plaque de ventilateur 5S1137002 Compartiment à câblage 5S1137003 Faisceau d'alimentation d’arrivée 5S9199703 Assemblement de ventilateur 5S1140018 Interrupteur du moteur 5S1136070 Interrupteur du lampe 5S4199018 Plaque d’interrupteur 5S1142010 Bouton...
  • Page 12 REMARQUE www.airkinglimited.com 6728028 Rev. L 12-15 12 of 12...

Ce manuel est également adapté pour:

Essev30

Table des Matières