5. PROGRAMMATION
5.2 Programmation avancèe
IL EST UTILISÉ POUR RÉGLER LE
COURANT MAXIMAL
DE SURCHARGE DU MOTEUR
RANGE 0.5 ÷ 18.0A (SA640.xx)
RANGE 0.5 ÷ 90.0A (SA650.xx)
MAN. INDIQUE QUE LA VALEUR
DU COURANT MAXIMAL A ÉTÉ
DÉFINIE MANUELLEMENT
COURANT MAXIMAL
AUT.
16.5 A
AUT. INDIQUE QUE LA VALEUR DU
COURANT MAXIMAL A ÉTÉ DÉFINIE
AVEC L'AUTO-APPRENTISSAGE
IL EST UTILISÉ POUR RÉGLER
LE DÉSÉQUILIBRE
DU COURANT SUR LES PHASES
RANGE: OFF - 5% - 10% - 15%
OFF EXCLUT LE
DÉSÉQUILIBRE DES PHASES
OFF. EXCLUT LE CONTRÔLE SUR
LE COURANT MINIMAL
IL EST UTILISÉ POUR RÉGLER
LE COURANT MINIMAL
DU MOTEUR
RANGE 0.5 ÷ 15.0A (SA640.xx)
RANGE 0.5 ÷ 33.0A (SA650.xx)
MAN. INDIQUE QUE LA VALEUR
DU COURANT MINIMAL A ÉTÉ
DÉFINIE MANUELLEMENT
COURANT MINIMAL
AUT.
9.9 A
AUT. INDIQUE QUE LA VALEUR DU
COURANT MINIMAL A ÉTÉ DÉFINIE
AVEC L'AUTO-APPRENTISSAGE
IL EST UTILISÉ POUR RÉGLER
LE DÉLAI D'INTERVENTION POUR LA
PROTECTION SUR LE COURANT
RANGE 1 ÷ 8s
DELAI COURANT
4 s
10
IL EST UTILISÉ POUR RÉGLER
LE TEMPS DE REARMEMENT
SUR LE COURANT MINIMAL
RANGE 1min ÷ 99h 59min
REARMEM. COURANT
MINIMAL 0h 5m
REARMEM. COURANT
MINIMAL
OFF
OFF EXCLUT LE REARMEMENT
COURANT MINIMAL
REARMEM. COURANT
MINIMAL
OFF
IL EST UTILISÉ POUR RÉGLER LE
NOMBRE MAXIMUM DE DÉMARRAGES
DU MOTEUR DANS UNE HEURE
MAX DEBUTS PAR
HEURE
10
OFF. EXCLUT LE CONTRÔLE
SUR LES DEMARRAGES
DES MOTEUR
MAX DEBUTS PAR
HEURE
OFF
MAX DEBUTS PAR
HEURE
OFF