All manuals and user guides at all-guides.com
11. Replace the pressure release
tube. Tighten nuts.
12. Replace the outlet tube and
tighten nuts.
13. Replace shrouds and console.
14. Perform the Break-in Procedure.
See "Break-in Procedure" in the
Operation section.
To Replace Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug unit.
3.
Remove the regulator ring and
remove the console cover.
gauge and quick connect. Orient
outlet pressure gauge to read
correctly. Tighten quick connect
with wrench.
Regulator
Ring
4.
Using an adjustable wrench
loosen pressure relief tube nut at
air tank and pressure switch.
5.
Using an adjustable wrench,
rotate the pressure switch
assembly as shown.
Regulator
Outlet
Pressure
Gauge
6.
Remove the outlet pressure
gauge, tank pressure gauge, and
quick connect (if equipped) from
the regulator.
7.
Remove the regulator.
8.
Apply pipe sealant tape to the
nipple.
9.
Assemble the regulator and
orient as shown.
NOTE: Arrow indicates flow of air.
Make sure it is pointing in the
direction of air flow.
Cover
10. Reapply pipe sealant to outlet
pressure gauge, tank pressure
gauge, and quick connect.
11. Reassemble outlet pressure
gauge, tank pressure gauge, and
quick connect. Orient outlet
pressure gauge and tank
pressure gauge to read correctly.
Tighten quick connect with
wrench.
12. Rotate pressure switch assemble
into correct position.
13. Replace console cover and
regulator ring.
Tank
Pressure
Gauge
Quick
Connect
19- ENG
Regulator
Arrow
D27610