HOW TO CONNECT AN ELECTRIC LOCK
The "door-open" relay can operate either as "dry contact" or "capacitive discharge" mode.
• In "dry contact" operation mode the relay works in a traditional way, a power supply or a power source is needed to operate the
lock (12-24Vac/dc 2A max), and activation lasts according to the door opening time programmed.
• In "capacitive discharge" operation mode the relay's contacts, when active, supply directly the lock (12Vac/dc 1A max) for a mo-
ment. You don't need a power supply for the lock and the door opening time programmed does not affect the activation time.
A possibile deterioration of the mechanical performance of the electric lock, might cause the "capacitive discharge" to malfunction
in time. In case the electric lock is used in very dusty environments or in peculiar climate conditions, we suggest to use the "open
door" relay in "dry contact" mode.
Using CAPACITIVE
Art.4384-1 (R0.1)
Fig. 5 Using capacitive discharge
OPERATION
Once the device has been programmed and connected correctly, it will generate upon each pressing of a push button, a code correspond-
ing to the PHONE ID (address programmed on the 8 way dip-switch inside each telephone) of the telephone being called.
Title:
Title:
TO CALL A USER
Titolo:
Titolo:
Press the relevant button to call the user: 2 quick beeps will indicate if the system is busy, otherwise the call will be signalled by a
Videx Electronics S.p.A.
Via del Lavoro 1, 63846 Monte Giberto (FM)
slow intermittent acoustic signal until the call is answered, the conversation time expires (programmable time) or the call is inter-
Phone: +39 0734 631669 - Fax +39 0734 631669
www.videx.it - info@videx.it
rupted by pressing a push button for a minimum of 2 seconds.
A short intermittent acoustic signal plus the relevant LED switched ON indicates that the door is open or the service relay is activat-
ed. If a wrong push button is pressed or if there is no answer, a new call will cancel the previous one.
MOUNTING NOTES
When an expansion button module (Art. 404x)
is used combined with speaker units with inbuilt
camera (Art. 4384-1, Art. 4384-2, Art. 4384X-1,
Art.  4384X-2) remember to set the expansion
modules properly in order to avoid overwriting
the addresses; indeed the inbuilt buttons ad-
dresses are already set (Fig. 7).
Art. 4384/4384X -
Installation instructions
Using CAPACITIVE
12Vac/dc 1A Max
DISCHARGE
DISCHARGE
1
Unit ID:
Unit ID:
Art.4384-1 (R0.1)
ON
ON
1
2
3
4
5
6
7
8
1
2
EXPANSION
EXPANSION
BUTTONS
BUTTONS
12Vac/dc
12Vac/dc
Videx Electronics S.p.A.
Notes:
Notes:
.
.
Via del Lavoro 1, 63846 Monte Giberto (FM)
Note:
Note:
Phone: +39 0734 631669 - Fax +39 0734 631669
.
.
www.videx.it - info@videx.it
Fig. 7
Using separate P.S.U.
1
Art.4384-1 (R0.1)
3
5
6
7
8
4
12Vac
Fig. 6 Using separate P.S.U.
24Vac/dc 2A Max using other power supplies
Art. 4384 -Art. 4384X
1
10
9
8
7
6
- 4 -
Using separate P.S.U.
12Vac 1.6A Max using Art. 321
24Vac/dc 2A Max using other power supplies
1
Unit ID:
Unit ID:
Art.4384-1 (R0.1)
ON
ON
1
2
3
4
5
6
7
8
1
EXPANSION
EXPANSION
BUTTONS
12Vac
12Vac 1.6A Max using Art.321
12Vac 1.6A Max using Art.321
24Vac/dc 2A Max using other power supplies
Nr.7
switch
ON
OFF
1 2 3 4 5 6
7
8
Art. 404x jumper
n=5
R
1
13V
13V
ART.321
ART.321
230V
230V
3
5
6
7
8
2
4
230V
230V
50/60 Hz
50/60 Hz
BUTTONS
Data creazione:
Foglio
Data creazione:
Foglio
28/11/2022
28/11/2022
1
/ 1
1
/ 1
Data modifica:
Data modifica:
28/11/2022
28/11/2022
Autore:
Autore:
Lorenzo Silla
Lorenzo Silla
Cod.File:
Cod.File:
esvk-g008.dwg
esvk-g008.dwg
2
1
10
9
8
7
6
66251850 - V3.3 - 30/11/22

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

43844384x4384x-04384-14384x-14384-2 ... Afficher tout

Table des Matières