Replacing The Activated Charcoal Filter; Light Replacement - ROBLIN Cubix Centrale 600 Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• The filter is not washable and cannot be regenerated. It must be replaced when led S1
flashes or at least every 4 months. The alarm signal will only light up when the extractor
motor is switched on.
Alarm signal activation
• In Recirculation version Hoods, the Filter saturation alarm can be enabled on installation or
at a later date. Turn the Lights and the suction Motor off.
• Disconnect the Hood using the Main switch or the double-pole switch on the mains power
supply.
• Restore the connection by pressing and holding T1.
• Release the button. All five LEDs are turned on
• Within 3 seconds press T1 until LEDs T1 and T4 flash in confirmation:
LED flashes twice - Activated charcoal filter saturation alarm ENABLED
LED flashes once - Activated charcoal filter saturation alarm DISABLED

REPLACING THE ACTIVATED CHARCOAL FILTER

Alarm signal reset
• Switch off the lights and extractor motor.
• Press button T3 for at least 3 seconds, until the leds start to
flash.
Replacing the Filter
• Pull the Comfort Panel to open it.
• Remove the metal grease filters
• Remove the saturated activated carbon filter by releasing the
fixing hooks
• Fit the new filter by hooking it into its seating
• Replace the metal grease filters.
20 W halogen light.
• Remove the 2 screws fixing the Lighting support, and pull it
out of from the Hood.
• Extract the lamp from the Support.
• Replace with another of the same type, making sure that the
two pins are properly inserted in the lamp holder socket holes.
• Replace the Support, fixing it in place with the two screws re-
moved as above.
EN
Activated charcoal filter (Recirculation version)
Lighting

LIGHT REPLACEMENT

2
27
7

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Cubix 600

Table des Matières