Read these instructions thoroughly before beginning work.
Please leave instructions for customers. These instruction contain maintenance
and warranty information.
If necessary, remove the existing toilet.
IMPORTANT!
Due to the powerful performance of our Cyclone, G-Max, E-Max and Power Gravity
flushing systems, they are not specified for back-to-back installations. The only
means of installing these toilets in a back-to-back situation is when the toilet drain
connections incorporate a WYE fitting. Please contact your builder or contractor prior
to this installation.
For your new TOTO toilet to fit correctly, the rough-in, the distance between the
finished wall to the center of the
closet flange, must be at least
12 inches for most models.
NOTE:
Models
rough-in have model numbers
ending with ".10", for example
C744EF.10.
1) Clean any debris out of the closet flange
and then install new mounting bolts
(not supplied) into the slots of the closet
flange (see Illustration 1). The head of the
bolt should be inserted into the slot with
its threads facing upward.
2) Carefully turn the toilet upside down
onto some padding. Firmly press a new
bowl wax ring (not supplied) onto the
circular recess around the toilet bowl's
horn (see Illustration 2). Turn the toilet
upright and gently lower into position
over the closet flange. With toilet
properly aligned, press firmly on both
sides of toilet rim to set the bowl wax
ring (see Illustration 3).
CAUTION: Do not move the bowl after
the bowl wax ring is set. Thread the nuts
and tighten evenly until bowl is snug to
closet flange. Install the bolt caps (see
Illustration 3).
CAUTION: Do not over-tighten the nuts
as damage to the china bowl may result.
BEFORE INSTALLATION
Double Combination WYE / 1/8 Bend
YES
with
10"
INSTALLATION PROCEDURE
Double Sanitary Tee / Sanitary Cross
Finished Wall
Supply
Valve
"RI"
Ill. 1
Ill. 2
Ill. 3
Bolt Cap
Nut *
Washer *
Base Cap
Bowl Base
* Not Supplied
4
NO
C/L
Closet
Flange
Wax Ring
Horn
Three Points of Contact