Installer setup tables
Setup functions
431
Ventilation Lockout Temperatures
433
Ventilation Lockout High Outdoor Humidity
450
A-Coil Low Temperature Cutoff
500
Replacement reminders
502
Furnace filter runtime counter
525
Installer Custom Reminders
530
Adaptive Intelligent Recovery
540
Number of schedule periods
580
Minimum compressor off time
600
Temperature range stops
640
Clock format
650
Extended fan on time(s)
670
Keypad lock
680
Temp. control (heat)
690
Temp. control (cool)
695
Finish on High Heat Stage
696
Finish on High Cool Stage
700
Indoor display offsets
Customer contact information (optional, but recommended)
1100
Dealer name
1150
Dealer phone number
1200
Dealer email address
1250
Dealer website
1300
Dealer Message
Note: All installer options, including Dealer name, contact information and message can
be set up as a file and downloaded via the USB port on the thermostat.
Restore Factory Defaults
Under the Menu, Installer Options and Advanced Options is a button to
"restore factory defaults."
If pressed, it will reset the program schedule and most installer setup
options (exceptions: 1350, 1355, 1400, 1405, 1410, 1500 and 450) and
disconnect the thermostat from the Equipment Interface Module.
(factory default setting listed, other options available)
11
2-wire Prestige® IAQ and RF EIM
None
Off; 75° dewpoint if On
None
Off
Count heat and cool
Add Customer Reminder
On
4
5 minutes
90° F (32° C); 60° F (15.5° C)
12-hour
Off
Unlocked
Standard
Standard
No
No
No offset
Your company name
Your telephone contact
Your email address
Your web site
Edit
69-2445EFS—03