Maintenance and Service

MAINTENANCE AND SERVICE
EN
• Maintenance and repairs to the machine must be carried out by a qualified personnel. Our company will not
be responsible for any accidents that may occur by unauthorized interventions.
• Parts that will be used during repair can be obtained from our authorized services. The use of original spare
parts will extend the life of your machine and prevent performance losses.
• Always contact the manufacturer or an authorized service designated by the manufacturer.
• Never make interventions yourself. In this case the macufacturer warranty is no langer valid.
• Always comply with the applicable safety regulations during maintenance and repair.
• Before performing any work on the machine for repair, disconnect the machine's power plug from the power
supply and wait for 10 seconds for the capacitors to discharge.
4.1 Maintenance
Every 3 Months
• Do not remove the warning labels on the device. Replace the worn/torn labels with
the new ones. Labels can be obtained from the authorized service.
• Check your torch, clamps and cables. Pay attention to the connections and the
durableness of the parts. Replace the damaged/defective parts with the new ones.
Do not ever make additions to/repair the cables.
• Ensure adequate space for ventilation.
• Before starting welding, check the gas flow rate from the tip of the torch with a flow
meter. If the gas flow is high or low, bring it to the appropriate level for the welding
process.

Every 6 Months

• Clean and tighten fasteners such as bolts and nuts.
• Check the lead of the electrode pliers and earth pliers.
• Open the side covers of the machine and clean with low pressure dry air. Do not
apply compressed air to electronic components at close range.
• Periodically replace the water in the tank of the water cooling unit with fresh, hard
water and protect it against freezing with antifreeze.
NOTE: The above mentioned periods are the maximum ones that should be applied if no problems are
encountered in your device. Depending on the work load and contamination of your work environment,
you can repeat the above processes more frequently.
Never operate the machine when covers are open.

4.2 Non-Periodic Maintenance

• The Wire Feeding Mechanism must be kept clean and the roller surfaces must not be
lubricated.
• Always remove any deposits on the mechanism with dry air each time you replace a
welding wire.
• The consumables on the torch should be cleaned regularly. It should be replaced if