Technical Information
EN
CC / CV
Temperature (C°)
Duty Cycle
As defined in the standard EN 60974-1, the duty cycle rate includes a time period of 10 minutes.
6 min.
For example, if a machine specified as 250A at %60 is to be operated at 250A, the machine can weld / cut
without interruption in the first 6 minutes of the 10 minutes period (zone 1). However, the following
4 minutes should be kept idle for the machine cool down (zone 2).
USER MANUAL
Three Phase Transformer Rectifier
Constant Current / Constant Voltage
Direct Current
MIG/MAG Welding
Mains Input 3-Phase Alternating
Current
Suitable for Operation at Hazardous
Environments
4 min.
6 min.
Duty Cycle
X
Open Circuit Voltage
U0
Mains Voltage and Frequency
U1
Rated Welding Voltage
U2
Rated Mains Current
I1
Rated Welding Current
I2
Rated Power
S1
Protection Class
IP21S
4 min.
6 min.
SMART SERIES
Time (min.)
4 min.