Tony
1. TECHNICAL DATA
As a stove of construction type 1, it is possible to connect it
to the chimney together with an exisiting other stove or
another hearth for solid fuels, as long as the chimney
dimensioning complies with DIN 4705, Part 3.
TECHNICAL DATA
Height
Width
Depth
Weight
Flue pipe outlet diameter
Nominal thermal output (EN 13240)
Maximum thermal capacity
Smallest heating capacity
2.
IMPORTANT INFORMATION
The installation and operation information given here is of
general nature. National and European standards, local
and building regulations as well as fire prevention laws
must be observed during the operation of the stove
General safety instructions for the
operation of your stove
Thoroughly read the entire manual before starting up
your stove and observe the caution notices.
Your heating unit may not be moved without
approved means of transport with sufficient load-bearing
capacity.
Your heating unit is not suitable to be used as a stand
or as a ladder.
Please keep in mind that your
stove's surface heats up considerably
during
operation.
We
recommend wearing a safety mitten
when operating your stove.
Attention – stove varnish is no rust prevention!
Make your children aware of this particular danger
and keep them at a distance from the heating unit
whenever it is in operation.
Only burn approved fuels and materials listed in the
chapter "Clean Burning".
The burning or placing of flammable or explosive
materials, like empty spray cans and such like into the
firebox as well as the storage of such materials in the
immediate vicinity of your heating unit is strictly forbidden
due the danger of explosion.
Do not wear loose or flammable clothing when adding
fuel to the fire.
Placing non-heat-resistant objects on the heating unit
or in the vicinity of the heating unit is forbidden.
1221 mm
960 mm
685 mm
255/269 kg
180 mm
10 kW
14 kW
5 kW
.
therefore
4
Room heating capacity
(depending on building insulation)
Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the
calculation of the chimney measurements in
accordance with DIN 4705, Part 2
Fluegas mass flow
Fluegas temperature
Minimum feed pressure
Nominal thermal output
Do not lay laundry onto the stove for drying. Laundry
hung up to dry must be kept at a safe distance from the
stove because of the danger of fire.
This woodstove is no "
hold embers for at least 4 hours).
During the operation of your heating unit it is
forbidden to use flammable or explosive materials in the
same or an adjacent room to the one in which your heating
unit is located.
Setting up your stove
Required safety distances
distances – see name plate - in Fig. 2) - towards
flammable materials
a > 800 mm
b > 150 mm
c > 000 mm (*1)
d > 1090 mm (*2)
(a – toward the front in the radiated area)
(b – to the sidel panel/glass front)
(c – to the back)
*1: A wall installation with a 0 mm distance to a flammable
wall is only allowed if the optional heat protective plate is
mounted.
*2: If a flammable ceiling needs to be protected, the
distance between the Designkamin top end and the ceiling
must be not less than 1090 mm
english
130–360 m³
closed
8,1 g/s
closed
313 °C
closed
12 Pa
at 0.8 times
10 Pa
n. ther. outp.
slow combustion stove" (must
(Minimum
.