Electrical Connections

energized.
• 12-24VDC Models – Connect the power source positive (+) lead to the red wire and
connect the power source negative (-) lead to the black wire.
• 120-240VAC 50/60Hz Models – Connect the line (L or L1) power source lead to the black
wire and connect the neutral (N or L2) power source lead to the white wire. Connect ground
to the green/yellow wire if required.
Changing the Light Pattern with Power Select™: FB2LED is factory set to 60FPM, change to
120FPM or steady on by cycling the power.
1. Enter programming mode by turning the input power on and off three times at a rate of 1 cycle
per second. This timing cycle must be adhered to or the programming request will be ignored.
2. To switch to the next light pattern, cycle the power from off to on. Repeat this step until you
arrive at the desired flash pattern.
3. To exit programming mode and set the pattern in memory, let the light operate for at least 15
seconds or turn power off for more than 5 seconds.
Testing/Operating: After installation, test the system to verify each signal operates and
establish a program for periodic testing of the device. Provide copy of these instructions to all
operating personnel.
Ordering Replacement Parts and Accessories: If your unit requires a part not listed below, it
must be either replaced or repaired.
Description
PCBA, 12-24VDC, Amber, Red, Green
PCBA, 12-24VDC, Clear, Blue
PCBA, 120-240VAC, Amber, Red, Green
PCBA, 120-240VAC, Clear, Blue
Corner Mount Bracket Assembly
Wall Mount Bracket Assembly

Technical Assistance:

signalsupport@fedsig.com.
Repair Service: A return authorization is required. Contact your Authorized Distributor or
Federal Signal Customer Support at +1-708-534-4756 or iordersup@fedsig.com. Defective
products under warranty will be repaired or replaced at Federal Signal's discretion. Lamp failures
excluded.
Product Returns: Product returns require a return authorization from Federal Signal prior
to returning the product. Please contact your Authorized Federal Signal Distributor for more
information regarding our return policy or to request a product return.
2645 Federal Signal Drive, University Park, Illinois 60484
Additional translations available at www.fedsig.com
Traducciones adicionales disponibles en www.fedsig.com
Customer Support 1-800-344-4634+1-708-534-4756, iordersup@fedsig.com
Technical Support 1-800-755-7621+1-708-587-3587, signalsupport@fedsig.com