5. When the fence locking handle (B) Fig. 16, is pushed to the
down position, the fence assembly (C) should be completely
clamped to the guide tube. If the fence
not completely clamped to the guide tube when the handle
is pushed down, as shown, lift up handle (B) and raise fence
off the guide tube as shown in Fig. 15. Slightly tighten the
two adjusting screws (J) and (K) (if the fence is too loose) or
loosen (if the fence is too tight), using a 3/16" Allen wrench,
not supplied. NOTE: Screws (J) and (K) should be tightened
or loosend an equal amount. Replace the fence back on
the guide tube and recheck to see if the fence assembly
is completely tightened to the guide tube with the locking
handle (B) pushed down. Adjust further if necessary.
IMPORTANT: AFTER ADJUSTING THE FENCE
CLAMPING ACTION, RECHECK TO SEE THAT THE
FENCE IS STILL PARALLEL TO THE MITER GAGE
SLOT AND ADJUST AS NECESSARY.
6. When clamping the fence assembly (C) to the guide tube,
J
FIG. 15
C
FIG. 16
ASSEMBLY
make certain the camfoot (P), Fig. 17, is hanging down and
against the locking handle (B), and not caught on top of the
assembly (C) is
guide tube.
7. To move the fence along the guide tube, simply lift up the
locking handle (B) Fig. 18, as shown, slide the fence to
the desired position on the guide, and push down locking
handle (B) Fig. 16 as shown, to lock in position. NOTE: A
magnet is provided to hold the handle in the up
position when moving the fence.
B
K
B
10
C
P
FIG. 17
FIG. 18