TESTING
NB!
Have a qualified electrician make the tests.
WARNING!
Risk of electric shock. Tests must be carried out while the
power is on.
•
Check the power terminals of the circuit breaker and the
main module. Bad connections may cause a fire. Switch the
power on from the switchboard on by using the circuit breaker.
The screen will flash for a moment. The device is ready for use.
•
Check the door switch: close the steam room's door. Turn the
control console on. Set the temperature. Turn the heating on.
Contactors must switch on. Open the door. Contactors must
switch off in 5-10 seconds. Close the door. Contactors must
switch on again.
•
Check the temperature sensor:
•
Install the protection. Switch the power off from the sauna's
switchboard for 15 seconds and then on again. The control
console must have turned off and when it is turned on, it
must show the current temperature.
•
The temperature is renewed periodically, 1 degree at a time
– therefore it may take some time to reach the actual tempe-
rature reading.
•
Set the desired temperature to 122
on. Check that the desired temperature is maintained. Turn
the heating off.
•
Set the desired temperature. Turn the heating on. Check
that the temperature is achieved and maintained.
F (50
C). Turn the sauna
o
o