CONTROL PANEL – UKU
With a wooden housing
•
Remove the back cover of the UKU control panel to attach it to
the wall.
•
Attach the back cover to the wall so that the upper edge of the
control panel is at eye level.
•
Connect the power cable with the screw terminal of the device.
•
Attach the device to the back cover that has been placed on the
wall. Secure it with screws from the sides.
With a plastic housing
•
Connect the power cable with the cable screws of the UKU control
panel.
•
Pull off the control panel control knob.
•
Attach the device with screws to the wall.
•
Replace the control knob to the control panel.
MAIN MODULE
•
When installing inside the steam room, the enclosure should be
placed 4-19.7 in (10-50 cm) above the floor.
•
Fix the unit to the wall with 4 screws.
•
Do not attach the main module to the ceiling or inclined surfaces.
•
Connect the cables of the UKU control panel, temperature sen-
sor, and door switch through a cable gland to the enclosure and
main module, see figure.
•
Connect the power cable (240V 2(N)~) of the control console
through the cable glands to the main module, see figure.
DOOR SENSOR
The door switch consists of two parts: a sensor and a magnet.
•
Use a 13/64 in (5mm) diameter drill when installing a door
sensor recessed in the door frame.
•
Install the door sensor at a maximum height of 15.8 in (40 cm)
from the floor.
1
2
3
7