Door Sensor - HUUM UKU Mode D'emploi

Masquer les pouces Voir aussi pour UKU:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CONTROL PANEL – UKU
With a wooden housing
Remove the back cover of the UKU control panel to attach it to
the wall.
Attach the back cover to the wall so that the upper edge of the
control panel is at eye level.
Connect the power cable with the screw terminal of the device.
Attach the device to the back cover that has been placed on the
wall. Secure it with screws from the sides.
With a plastic housing
Connect the power cable with the cable screws of the UKU control
panel.
Pull off the control panel control knob.
Attach the device with screws to the wall.
Replace the control knob to the control panel.
MAIN MODULE
When installing inside the steam room, the enclosure should be
placed 4-19.7 in (10-50 cm) above the floor.
Fix the unit to the wall with 4 screws.
Do not attach the main module to the ceiling or inclined surfaces.
Connect the cables of the UKU control panel, temperature sen-
sor, and door switch through a cable gland to the enclosure and
main module, see figure.
Connect the power cable (240V 2(N)~) of the control console
through the cable glands to the main module, see figure.

DOOR SENSOR

The door switch consists of two parts: a sensor and a magnet.
Use a 13/64 in (5mm) diameter drill when installing a door
sensor recessed in the door frame.
Install the door sensor at a maximum height of 15.8 in (40 cm)
from the floor.
1
2
3
7