7.6 Periodic maintenance

Speak to your local Authorised Service
Centre periodically to check the

8. TROUBLESHOOTING

WARNING!
Refer to Safety chapters.
8.1 What to do if...
Problem
There is no spark when you
try to activate the spark gen‐
erator.
The flame extinguishes im‐
mediately after ignition.
The flame ring is uneven.
The control panel brightness
is reduced or it switches off.
The control knob pilot lights
turn on after connecting the
hob to the mains or after a
power outage.
Hob²Hood function does not
work.
conditions of the gas supply pipe and the
pressure adjuster, if fitted.
Possible cause
The hob is not connected to
an electrical supply or it is
connected incorrectly.
The fuse is blown.
Burner cap and crown are
placed incorrectly.
Thermocouple is not heated
up sufficiently.
Burner crown is blocked with
food residues.
The temperature of the plate
is high. To ensure long life‐
time of the display the bright‐
ness is reduced depending
on the temperature of the
hob. Above a certain tem‐
perature the control panel
switches off.
Pilot light test.
You covered the control pan‐
el.
ENGLISH
Remedy
Check if the hob is correctly
connected to the electrical
supply.
Make sure that the fuse is
the cause of the malfunction.
If the fuse is blown again
and again, contact a quali‐
fied electrician.
Place the burner cap and
crown correctly.
After lightning the flame,
keep the knob pushed for
equal or less than 10 sec‐
onds.
Make sure that the injector is
not blocked and the burner
crown is clean.
Let the hob cool down.
Refer to "Installation".
Remove the object from the
control panel.