Dell PowerEdge 2900 Guide De Mise En Route page 14

Masquer les pouces Voir aussi pour PowerEdge 2900:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
Physical (continued)
Depth
Weight (maximum configuration)
Tower (without bezel)
Height
Width
Depth
Weight (maximum configuration)
Environmental
NOTE:
For additional information about environmental measurements for specific system
configurations, see www.dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
Altitude
Operating
Storage
12
Getting Started With Your System
66.13 cm (26.04 in) does not include control
panel or bezel; control panel adds an additional
1.3 cm (.51 in)
45.36 kg (100 lb)
47.89 cm (18.85 in) with feet, no casters
22.66 cm (8.92 in)
66.13 cm (26.04 in) does not include control
panel or bezel; control panel adds an additional
1.3 cm (.51 in)
49.9 kg (110 lb)
10° to 35°C (50° to 95°F)
–40° to 65°C (–40° to 149°F)
20% to 80% (noncondensing) with a maximum
humidity gradation of 10% per hour
5% to 95% (noncondensing)
0.26 G from 5–350Hz for 2 min in the Z axis
1.54 G from 10–250 Hz for 15 min in all
orientations
One shock pulse in the positive z axis (one pulse
on each side of the system) of 41 G for up to 2 ms
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G for up to 2 ms
–16 to 3048 m (–50 to 10,000 ft)
–16 to 10,600 m (–50 to 35,000 ft)

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ecm01

Table des Matières