TROUBLESHOOTING YOUR REFRIGERATED DRAWERS
Before You Call for Service
If the unit appears to be malfunctioning, read through this
manual first. If the problem persists, check the trouble-
shooting guide below. Locate the problem in the guide and
refer to the cause and its remedy before calling for service.
The problem may be something very simple that can be
solved without a service call. However, it may be required
to contact your dealer or a qualified service technician.
Electrocution Hazard
form maintenance on the unit until the main electrical power
has been disconnected. Turning the unit control "OFF"
does not remove electrical power from the units wiring.
Problem
Unit not cold enough.
Unit too cold.
No interior light in drawer com-
partments.
Light will not go out when drawer
is closed.
Noise or Vibration.
Unit will not run.
All manuals and user guides at all-guides.com
- Never attempt to repair or per-
Possible Cause
•
Control set too warm.
•
Content temperature not stabi-
lized.
•
Excessive usage or prolonged
drawer openings.
•
Airflow to front grille blocked.
•
Drawer gasket not sealing prop-
erly.
•
Control set too cold.
•
Drawer gasket not sealing prop-
erly.
•
Failed LED interior light assem-
bly.
•
Drawer not activating light switch. •
•
Unit not level.
•
Unit turned off.
•
Power cord not plugged in.
•
No power at outlet.
•
Adjust temperature colder, (See "Set the
desired temperature" on page 15). Allow
24 hours for temperature to stabilize.
•
Allow temperature to stabilize for at least
24 hours.
•
Airflow must not be obstructed to front
grille. See "clearances" on page 4.
•
Adjust or replace drawer gasket.
•
Adjust temperature warmer. (See page
15, "set the desired temperature"). Allow
24 hours for temperature to stabilize.
•
Adjust or replace drawer gasket.
•
Contact a qualified AGA MARVEL service
technician.
Unit not level, level unit, (See page 4,
"leveling legs").
•
Level unit, see "Leveling Legs" on page
4.
•
Turn unit on. See "Start your Appliance"
on page 15.
•
Plug in power cord.
•
Check house circuit.
18
Remedy