Craftsman 919.724572 Mode D'emploi page 17

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

To Replace Regulator
1.
Release all air pressure from air
tank. See "To Drain Tank" in the
Maintenance section.
2.
Unplug unit.
3.
Using an adjustable wrench
remove the outlet pressure
gauge and quick connect from
the regulator.
Regulator
4.
Remove the regulator.
5.
Apply pipe sealant tape to the
nipple on the standpipe.
Outlet
Pressure
Gauge
Quick
Connect
Nipple
17- ENG
6.
Assemble the regulator and
orient as shown.
Regulator
NOTE: Arrow indicates flow of air.
Make sure it is pointing in the
direction of air flow.
Regulator
7.
Reapply pipe sealant to outlet
pressure gauge and quick
connect.
8.
Reassemble outlet pressure
gauge and quick connect. Orient
outlet pressure gauge to read
correctly. Tighten connect with
wrench.
Arrow
D27446