Conrad Electronic 197720 Notice D'emploi page 34

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The following combinations result for the option value in commands 4 and 5:
Option
0
1 (default setting)
2
3
Commands 6 and 7 – Activating/deactivating individual relays
The relays addressed in the data byte are activated/deactivated directly without changes to the
remaining outputs.
Command 8 – Toggle
The switching command only has an effect on the relays addressed in the data byte.
This command refers to the 8 relays of the board: Bit 0 in the data value corresponds to relay
K1 (clamp X1), bit 1 with relay K2 (clamp X2) etc.
E.g. relay K7, relay K6 and relay K4 are activated (01101000). If relay K6 is supposed to be
deactivated and relay K5 activated, you have to send 48 (binary 00110000) with data.
34
Execution of broadcasts
no
yes
no
yes
Blocking of broadcasts
no
no
yes
yes

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

197730

Table des Matières