Environmental
NOTE:
For additional information about environmental measurements for specific
system configurations, see www.dell.com/environmental_datasheets.
Temperature
Operating
Storage
Relative humidity
Operating
Storage
Maximum vibration
Operating
Storage
Maximum shock
Operating
Storage
12
Getting Started With Your System
10° to 35°C (50° to 95°F) with a maximum
temperature gradation of 10°C per hour
NOTE:
For altitudes above 2950 feet,
the maximum operating temperature is
derated 1ºF/550 ft.
–40° to 65°C (–40° to 149°F) with
a maximum temperature gradation of
20°C per hour
20% to 80% (noncondensing) with
a maximum humidity gradation of
10% per hour
5% to 95% (noncondensing)
0.26 G at 5–350 Hz for 15 min
0.5 G at 3–200 Hz for 15 min
One shock pulse in the positive z axis
(one pulse on each side of the system) of
31 G for 2.6 ms in the operational orientation
Six consecutively executed shock pulses
in the positive and negative x, y, and z axes
(one pulse on each side of the system)
of 71 G for up to 2 ms