Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

20
20
Vestfrostsolutions.com
Vestfrostsolutions.com
SET THE PASSWORD FOR ADVANCED SETTINGS:
BACK
NEXT
PASSWORD
SET THE TEMPERATURE PROFILE:
BACK
NEXT
TEMPERATURE
PROFILE
Before use:
• Ensure the ambient temperature is witin the range og 5°C and 35°C�
• Make sure the appliance has been in a stable and levelled upright position for
at least one hour before pushing "ON" �
• Allow the appliance to operate at the desired temperature for a minimum of
12 hours before loading�
• Make sure there min 60 mm of space on all sides and above the appliance�
• Clean the inside o´f the cabinet using warm water with a mild detergent� Use
soft cloth rinse with clean water and dry thoroughly�
EN
- service code
- selection of the desired temperature profile
- recommendations for use and installation
and choice to activate the unit or use the
"DEMO" mode
EN

MAINTENANCE

TASK
Description
The compressor com-
1. Unplug unit from power supply
partment and the con-
2. Remove the lower panel.
denser must be kept
3. Use a vacuum cleaner to
free of dust and dirt.
remove
dust and dirt.
The door gasket(s)
1. Wipe the seal with a soft cloth
around the door must
and clean water
be cleaned regularly.
2. Check that it continues to
provide a tight seal.
Clean vacuum release
1. Excessive frost accumulation in
the vacuum release could restrict
air flow.
2. Brush away any loose frost
using a stiff nylon brush.
3. If frost has built up in the pipe
of the vacuum release, thrust
with a stick to remove the frost
inside.
Quick defrosting:
Small amounts of loose frost
can be removed using a plastic
scraper.
Defrost and clean the
Complete defrost:
chamber to prevent ice
1. Remove all products and place
building.
it in another ULT cabinet.
2. Disconnect the power supply.
3. Open the inner and outer
doors.
4. Wait until the ice has thawed.
5. Dispose of the ice and wipe
out
water.
6. Dry the interior of the device.
7 . Close the doors and start the
freezer
Replace the battery
Only a certified technician must
backup for the control-
replace the battery.
ler every 3 years.
Clean the interior and
1. Use warm water (max. 65°C)
exterior of the device.
with a little mild, perfume-free
detergent with a soft cloth.
2. Rinse with clean water and dry
thoroughly.
Note: It is important to prevent
water from entering the control
panel.
Vestfrost Solutions
Vestfrost Solutions
21
21
Frequency
Quar-
An-
3
As
terly
nual-
Years
need-
ly
ed
X
X
X
X
X
X
X

Publicité

Table des Matières
loading

Table des Matières