C. DETERMINATION OF THE NUMBER OF LOOP TURNS
WARNING :
For conformity reasons, in any situation, the antenna factor defined as the loop surface multiplied by the number of turns
should not exceed NA = 20
For example, if L=2m, Ea=1m and the number of turns=4, then the NA = 2x1x4 = 8 < 20.
Find hereafter the recommended values for the turns :
Area
< 3 m
3 - 5 m
6 - 10 m
D. SLOT DEPTH
Loop
sealant
WIRING
WARNING :
UL REQUIREMENT : The unit has to be mounted on a suitable UL recognized SWIV2 Relay Socket
Relay socket suggested
references :
• OMRON PF113A-D
• LUNDBERG R11
• MAGNECRAFT 70-465-1
• IDEC SR3P-05C
• ERSCE ES11
• CUSTOM CONNECTOR
CORPORATION OT11
ADJUSTMENTS
A. THE 3 CONFIGURATIONS
• Configuration # 1 : single loop detector (MATRIX-S)
• Configuration # 2 : dual loop detector in independent mode (MATRIX-D with dip switch #10 OFF)
• Configuration # 3 : dual loop detector in combined mode (MATRIX-D with dip switch #10 ON)
B. POTENTIOMETERS
PRESENCE TIME
1 min 10 min
1 H
Min
Max
5 H
Infinity
20 H
C. RELAY CONFIGURATIONS (Dip Switch #3)
The loop A activates the relay A and the loop B activates the relay B. With the dual loops in combined mode the relay A
provides the presence detection and the relay B provides the movement direction
Detection
No Detection
Number of turns
2
4
2
3
2
2
30 - 50 mm depending
on cable turns number
Clean and dry slots prior
to inserting cable
Do not remove the grease on the connector's pins
(SMA/SMA230)
SENSITIVITY
• A potentiometer for adjustment of the maximum duration of a presence detection :
0.5% 0.44%
from 1 min to infinity
0.34%
Min
• A potentiometer for adjustment of the linear sensitivity (∆f) for the loop A :
2 H
0.25%
from 0.005% to 0.5 %
Max
• A potentiometer for adjustment of the linear sensitivity (∆f) for the loop B :
0.18%
0.005%
0.1%
from 0.005% to 0.5 %
ACTIVE MODE
(dip switch #3 OFF)
NO
COM
NC
NO
COM
NC
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
Pin 9
Pin 10 : Relay 1 (NC)
Pin 11 : Relay 2 (NC)
(SMA2 with dip-switch # 10 OFF)
(SMA2 with dip-switch # 10 ON)
PASSIVE MODE
(dip switch #3 OFF)
NO
COM
NC
NO
COM
NC
: Power supply
: Power Supply
: Relay 2 (NO)
: Relay 2 (COM)
: Relay 1 (NO)
: Relay 1 (COM)
: Loop A
: Loop common and earth
: Loop B