Properties Vision and varieties -Gourmet -Plus.
Type: soapstone stove
Use: discontinue combustion of wood.
Nominally and space heating capacity up to: 7kW
Mass: 220kg
Flue gas flow: 9g/s
Flue gas temparature: 315°C
Local regulations
Your Altech stove must be positioned in accordance with the locally applicable (legal)
regulations including all national and European applying requirements and building
regulations. Your Altech dealer can advise you on this.
Flue
The flue must have a minimum inner diameter of 150 mm and has to meet the local and
building regulations. The draught of the flue must have a nominal value of between 10
Pa and 15 Pa. Your dealer can check this for you. It is recommended to be fitted with a
suitable bypass valve. If the door of the stove is equipped with the associated closing
spring the stove has been arranged for shared chimney canals.
In case of a chimney fire; close the air valve of the stove, extinguish the fire in the stove
with sand or soda and warn the fire brigade, try never to extinguish the fire with water.
Connecting piece
The connection between the stove and the chimney must be well sealed without hindering
the smoke or making it difficult to sweep the chimney.