Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
9.1
Blind-rivet setting tool is not in working order
Malfunction
The LEDs do not light up.
1 LED flashes.
4 LEDs flash.
Blind rivet is not set.
No rivet mandrel disposal.
10
Disposal
Most of the materials from which Hilti tools and appliances are manufactured can be recycled. The
materials must be correctly separated before they can be recycled. In many countries, your old tools,
machines or appliances can be returned to Hilti for recycling. Ask Hilti Service or your Hilti representative
for further information.
▶ Do not dispose of power tools, electronic equipment or batteries as household waste!
11

Manufacturer's warranty

▶ Please contact your local Hilti representative if you have questions about the warranty conditions.
10
English
Possible cause
The battery is not fully inserted.
Battery is discharged.
The battery is too hot or too cold.
Battery is discharged.
The battery is too hot or too cold.
Product momentarily overloaded.
Protection against overheating.
Overload protection.
Battery is discharged.
Jaws are dirty or worn.
Jaw housing not correctly screwed
on.
Spring weak or defective.
Use of the wrong nosepiece.
Nosepiece is worn.
Rivet mandrel wedged in jaws.
Steel sleeve is dirty.
Mandrel container is full.
Action to be taken
▶ Push the battery in until it
engages with a click.
▶ Change the battery and charge
the empty battery.
▶ Bring the battery to the recom-
mended working temperature.
▶ Change the battery and charge
the empty battery.
▶ Bring the battery to the recom-
mended working temperature.
▶ Release the control switch and
then press it again.
▶ Allow the product to cool down
and clean the air vents.
▶ Remove metallic residues .
→ page 8
▶ Change the battery and charge
the empty battery.
▶ Clean the jaws or, if applicable,
→ page 8 replace them.
▶ Screw the jaw housing on
correctly . → page 8
▶ Replace the spring . → page 8
▶ Change the nosepiece .
→ page 7
▶ Change the nosepiece .
→ page 7
▶ Remove the rivet-mandrel
residues from the jaw housing .
→ page 8
▶ Clean the steel sleeve .
→ page 8
▶ Empty the mandrel container .
→ page 7