Meccanica Fadini ELPRO 43 Manuel D'instructions page 11

For dardo 430
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Elpro 43
GB
24 Vdc max 50 mA relay
output or courtesy light
Programming
button
FORCE
LP
DURING
TRAVEL
PLUG-IN
ON
RADIO
CARD
OFF
CONNECTOR
1 2 3 4 5 6 7 8 9 10 11 12
ELPRO 43
E 43
L2
L4 L5 L6 L7
L0
1 2 3 4 5 6 7 8 9 10
NC
NC
General description: the electronic controller ELPRO 43 has been designed to control the gate operator type DARDO 430 at 230 Vac, mounted on single- or double-
swinging gates. 230 V - 50 Hz single-phase power supplied. The manufacturer is not liable for incorrect use of the controller, and reserves also the right to change and
update it to the latest standards of the art at any time.
IMPORTANT FOR THE INSTALLATION AND PROPER FUNCTIONING:
- The controller is to be installed in a sheltered, dry place.
- Make sure that power supply to the electronic controller be 230 V ±10%.
- In case of distances superior than 50 meters, increase the wire section.
- Fit the power supply to the controller with a 0,03 A, high sensibility, magneto-thermal circuit breaker.
- For the power supply, electric motor and asher use1,5 mm² section wires up to 50 m of distance.
- For the limit switches, photocells, command switches and accessories use 1 mm² section wires.
- If no stop button is used bridge terminals 3 and 6.
N.W.: for applications such as lights control, CCTV, etc. use solid state relays to prevent interference with the microprocessor.
DIAGNOSTICS BY LEDs:
L0 (Green ON) = Pair of photocells tted inside, no obstacle detected
L2 (Green ON) = Pair of photocells closing, no obstacle detected
L4 (Red OFF) = Open, switches ON when a command pulse to open is given
L5 (Red OFF) = Close, switches ON when a command pulse to close is given
L6 (Green ON) = Stop, switches OFF when a command pulse to stop is given
L7 (Red OFF) = Radio, switches ON when a transmitter button is pulsed
and the radio contact is made on terminals 3 and 7
L9 (Red OFF) = It illuminates in case of short circuit with 24 Vdc.
It switches OFF when the short circuit fault is removed
L13 (Green ON) = Safety edge open, switches OFF whenever the safety edge
is engaged
L14 (Green ON) = Safety edge close, switches OFF whenever the safety edge
is engaged
L16 (Red OFF) = Switches ON whenever a pedestrian command is given
E1 (Red ON) = Encoder led
E2 (Red ON) = Encoder led
ELECTRONIC CONTROLLER FOR DARDO 430 GATE OPERATOR
ON DOUBLE SWINGING GATES
DWELL
FORCE
DURING
TIME
1 s - 220 s
SLOWDOWN
OVERLOAD
L10
L13 L14
L16
11 12 13 14 15 16 17 18
TRANSFORMER
Capacitor
M2 Motor
12,5 μF
Capacitor
M1 Motor
12,5 μF
A1 C1 B1 A2 C2 B2 19 20
M1
M2
E1
E2
D1 E1 F1 D2 E2 F2
ENCODER
ENCODER
M1
M2
TROUBLE SHOOTING IN CASE OF FAILURE
- Make sure that power supply to the controller be 230 V ±10%
- Check all the fuses
- Check the photocells contact, it must be normally closed
- Make sure that no voltage drop be occurring between the control board and
the electric motor
- Check all the NC contacts in the control board
NOTE WELL:
All the possible connections to the control board terminals are also illustrated
in the respective instructions provided with the individual accessories.
11
F1 = 5 A
GENERAL
FUSE
21 22 23
green led, must be
ON all the time
red led ON
red led OFF all the time, it goes ON
when a contact is made or a pulse given
red led ashing:
controller on programming phase, waiting
for a pulse by the programming button

Publicité

Table des Matières
loading

Table des Matières