Description Of Operation - Craftsman 919.727550 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Know Your Air Compressor
READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustra-
tions with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual
for future reference.

Description of Operation

Become familiar with these controls before operating
the unit.
On/Auto/Off Switch: Turn this switch ON to provide
automatic power to the pressure switch and OFF to
remove power at the end of each use.
Pressure Switch: The pressure switch automatically
starts the motor when the air tank pressure drops
below the factory set "cut-in" pressure. It stops the
motor when the air tank pressure reaches the factory
set "cut-out" pressure.
Safety Valve: If the pressure switch does not shut off
the air compressor at its "cut-out" pressure setting,
the safety valve will protect against high pressure by
"popping out" at its factory set pressure (slightly high-
er than the pressure switch "cut-out" setting).
Outlet Pressure Gauge: The outlet pressure gauge
indicates the air pressure available at the outlet side
of the regulator. This pressure is controlled by the reg-
ulator and is always less than or equal to the tank
pressure.
Tank Pressure Gauge: The tank pressure gauge
indicates the reserve air pressure in the tank.
On/Auto/Off
Switch
Pressure
Switch
Tank
Pressure Gauge
Safety Valve
OPERATION
Outlet
Pressure Gauge
Regulator
9 - ENG
Regulator: Controls the air pressure shown on the
outlet pressure gauge. Pull the knob out and turn
clockwise to increase pressure and counterclockwise
to decrease pressure. When the desired pressure is
reached push knob in to lock in place.
Drain Valve: The drain
valve is located at the
base of the air tank and is
used to drain condensa-
tion at the end of each
use.
Cooling System (not shown): This compressor con-
tains an advanced design cooling system. At the heart
of this cooling system is an engineered fan. It is per-
fectly normal for this fan to blow air through the vent
holes in large amounts. You know that the cooling
system is working when air is being expelled.
Air Compressor Pump (not shown): Compresses air
into the air tank. Working air is not available until the
compressor has raised the air tank pressure above
that required at the air outlet.
Check Valve: When the
air compressor is operat-
ing, the check valve is
"open", allowing com-
pressed air to enter the air
tank. When the air com-
pressor reaches "cut-out"
pressure, the check valve "closes", allowing air pres-
sure to remain inside the air tank.
Drain
Valve
Check Valve
D23122

Publicité

Table des Matières
loading

Table des Matières