switch-1 for switch module installed in bay A1.
switch-2 for switch module installed in bay A2.
switch-3 for switch module installed in bay B1.
switch-4 for switch module installed in bay B2.
switch-5 for switch module installed in bay C1.
switch-6 for switch module installed in bay C2.
4. Enter racadm getniccfg -m switch-x at the prompt to verify that the address was correctly set.
NOTE
Refer to the documentation for the Dell Chassis Management Controller (CMC) for additional racadm command
details.
Using the Dell M8428-k CLI to set the IP address
To set the IP address of the switch module using the switch CLI via Serial port (rather than through the CMC), refer to
the Dell M8428-k Hardware Reference Manual under the section with this same section name.
Connecting to the converged network switch management interface
After succesfully setting the IP address of the switch module, a terminal emulator (Telnet, SSH) CLI connection can
be established to the converged switch module, from a remote management workstation, through the Chassis
Management Controller (CMC) Ethernet port. The management interface can be used for any additional
configuration of the switch module.
NOTE
The default switch module login/password the Admin account is: admin/password
Dell M8428-k Getting Started Guide
MHWKY A01
9 of 192