2.2.2

Interface description

)
Note!
ƒ
ƒ
MSP
14
1
Fig. 2−1
MSP DB25 socket and ASP8 Minidin 8 pole socket
Pin
Signal
1
n.c.
2
Tx RS232 OUT
3
Rx RS232 IN
4
RTS RS232 OUT
5
CTS RS232 IN
6
n.c.
7
Signal GND
8
n.c.
9 ... 16
Signals are not evaluated
17
n.c.
18
Signal is not evaluated
19 ... 21
n.c.
22 ... 25
Signals are not evaluated
n.c.
EDBPM−H505 DE/EN/FR 6.1
The EPM−H505 operating unit is equipped with the serial
interface MSP.
The EPM−H507 operating unit is equipped with the serial
interface ASP8.
Not connected
l
Technical data
Interface description
ASP8
8
7
6
5
4
3
2
1
h410_013
Pin
Signal
1
Rx RS232 IN
2
Tx RS232 OUT
3
n.c.
4
RTS RS232 OUT
5
CTS RS232 IN
6
n.c.
7
Signal GND
8
+5 VCC (reserved)
Electrical data