Thermistor Test - FloTech FT555F Mode D'emploi

Système de test automatique antidébordement
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

FloTech FT555F Automatic Overfill System Tester

THERMISTOR TEST

This test will test the API Thermistor signal from the trailer
mounted sensors or onboard monitor and report a Pass/ Fail.
OPERATION NOTE:
This tester is not compatible with the old style analog "green or
silver tipped sensors. These devices require the FT510 tester.
Step 1) Move the J-Slot thumb screws to the correct holes to match
the type of socket to be connected. Follow the "O" and "T"
markings on the plug body.
Step 2) Connect the FT555F Automatic Tester to the trailer socket.
Step 3) Press the ON/OFF button to turn on the FT555F Automatic
Tester. When "Press Key" screen appears press "TEST SELECT"
button three times so the "Thermistor Test" screen appears.
Step 4) Press the "GO" button to start the test. When the test is
complete the screen will display the PASS / FAIL status and a
wet/dry status for each of the compartments enabled during the
setup. A square under the number indicates a dry sensor or a dash
under the number indicates a wet or missing sensor. If connected to
an Onboard Monitor, dashed lines will show and no black bars.
Step 5) Press the "TEST SELECT" button to move on to a new
test, press "GO" to restart the test, or press the "ON/OFF" button
to turn the tester off.
Page 14
10784PA REV C
FT555F Truck Tester

Publicité

Table des Matières
loading

Table des Matières