FloTech FT555F Automatic Overfill System Tester

Setup Instructions

At the "Press Key" screen, pressing the SETUP key will enter the
setup mode. The first option will be:
MAX OPTIC COMPS = #
Press the GO button to toggle between 6 and 8 maximum number
of compartments. Generally the USA has a maximum of 6
compartments signals per one socket and Canada or European
regions will have a maximum of 8. Once the correct Maximum
Compartments count is showing, press TEST SELECT button to
move to the next SETUP screen.
MAX THERM COMPS = #
Press the GO button to toggle between 6 and 8 maximum number
of compartments. Generally the USA has a maximum of 6
compartments signals per one socket and Canada or European
regions will have a maximum of 8. Once the correct Maximum
Compartments count is showing, press TEST SELECT button to
move to the next SETUP screen.
Page 8
10784PA REV C
FT555F Truck Tester