Installation
Exemple d'installation : Dégagement zéro (métal) foyer foyer poêle
Vertical Cap
Storm Collar
"L" Vent
"L" Vent Flex
Section
© Travis Industries
(For Qualified Installers Only)
Cover Plate (non-combustible)
NOTE: you may need a short horizontal section here to
clear the lintel and allow the hopper lid to open.
4012412
Seal the cover
plate with silicone.
Allow room for the
hopper lid to open
19
Seal each vent
section (including
adapters, elbows,
etc...) by injecting a
liberal amount of
500° F. RTV
silicone into the gap
between sections,
unless otherwise
specified by the
manufacturer.
6" Min.
100-01270_000