Door Thickness Adjustment
• For 1³⁄4" thick doors, NO ADJUSTMENT IS REQUIRED.
Continue to step 2.
• For 1
⅜
" thick doors, install the optional spacers (see steps 2 and 3). No
further adjustment is required. Continue to step 2.
• For 1⅝", 2", or 2⅛" thick doors ONLY, complete the following door
thickness adjustment steps.
A
Remove adjustment plate by rotating counter-clockwise.
Remove door thickness insert using pin wrench.
Adjustment
plate
B
Reorient and replace the door thickness insert.
Door Thickness
1⅝"
2"
2⅛"
Chassis
side view
Door
thickness
insert
Door Thickness Insert
Door thickness
insert channel
NOTE: If door thickness insert is missing, align the
adjustment plate to marks on chassis:
Door
Thickness
Align adjustment plate with 1
⅜
1
"
spacers.
Tighten adjustment plate to bottom, then rotate a half
1⅝"
turn counterclockwise.
Align adjustment plate with 1
1³⁄4"
Align adjustment plate with 2" mark.
2"
Align adjustment plate with 2" mark, then rotate an
2⅛"
additional full turn counterclockwise.
C
Reinstall adjustment plate.
Tighten until door thickness insert enters notch in adjustment plate (or
align as described above).
Adjustment
" mark. Use optional
³⁄4
" mark.
³⁄4
1³⁄4"
2"