Control Panel - Omcan BC-IT-0103-T Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Operation
EXISTING ELECTRICAL SAFETY REGULATIONS.
THIS BASIC SAFETY REQUIREMENT MUST BE VERIFIED AND, IF IN DOUBT, REQUEST A CAREFUL
CONTROL OF THE PLANT BY PROFESSIONALLY QUALIFIED PERSONNEL.
THE CONSTRUCTOR DECLINES ALL RESPONSIBILITY FOR DAMAGES CAUSED BY THE DISRESPECT
OF AN EFFICIENT EARTHING OF THE PLANT.
Check that the appliance is perfectly levelled.
Regulate the adjustable feet if necessary.
Check that the plastic protective coating is removed from all external surfaces.
Check that the interior is washed with warm water and a neutral soap.
Check that the appliance is positioned as far as possible from heat sources.
Check that the free air circulation around the motor compartment is not obstructed.
Control the voltage and frequency of the mains distribution, they must fall within the given values: 230 V ±
10% ; 50 Hz / 400 V ± 10% ; 50 Hz

CONTROL PANEL

Each of the 6 keys activates different functions depending on the navigation level or the function currently
running.
Enables the quick selection of a blast chilling cycle.
Once a blast chilling cycle has been selected, it makes it possible to switch from temperature
controlled blast chilling to time controlled blast chilling and vice versa.
Within a menu or when setting a parameter: acts as the "ESC" key and returns the controller to
the page above.
N.B. When a cycle is in progress the key is not active; to stop the cycle press the "START" key
for 2 seconds.
Enables the quick selection of a blast freezing cycle.
Once a blast freezing cycle has been selected, it makes it possible to switch from temperature
controlled blast freezing to time controlled blast freezing and vice versa.
10

Publicité

Table des Matières
loading

Produits Connexes pour Omcan BC-IT-0103-T

Table des Matières