Déployer Threat Defense avec un Centre de gestion distant
Please enter 'YES' or press <ENTER> to AGREE to the EULA:
System initialization in progress.
You must change the password for 'admin' to continue.
Enter new password: ********
Confirm new password: ********
You must configure the network to continue.
You must configure at least one of IPv4 or IPv6.
Do you want to configure IPv4? (y/n) [y]:
Do you want to configure IPv6? (y/n) [n]:
Configure IPv4 via DHCP or manually? (dhcp/manual) [manual]:
Enter an IPv4 address for the management interface [192.168.45.45]: 10.10.10.15
Enter an IPv4 netmask for the management interface [255.255.255.0]: 255.255.255.192
Enter the IPv4 default gateway for the management interface [data-interfaces]:
Enter a fully qualified hostname for this system [firepower]: ftd-1.cisco.com
Enter a comma-separated list of DNS servers or 'none' [208.67.222.222,208.67.220.220]:
Enter a comma-separated list of search domains or 'none' []:
If your networking information has changed, you will need to reconnect.
For HTTP Proxy configuration, run 'configure network http-proxy'
Manage the device locally? (yes/no) [yes]: no
Configure firewall mode? (routed/transparent) [routed]:
Configuring firewall mode ...
Update policy deployment information
- add device configuration
- add network discovery
- add system policy
You can register the sensor to a Firepower Management Center and use the
Firepower Management Center to manage it. Note that registering the sensor
to a Firepower Management Center disables on-sensor Firepower Services
management capabilities.
When registering the sensor to a Firepower Management Center, a unique
alphanumeric registration key is always required.
a sensor to a Firepower Management Center, you must provide the hostname or
the IP address along with the registration key.
'configure manager add [hostname | ip address ] [registration key ]'
However, if the sensor and the Firepower Management Center are separated by a
NAT device, you must enter a unique NAT ID, along with the unique registration
key.
'configure manager add DONTRESOLVE [registration key ] [ NAT ID ]'
Later, using the web interface on the Firepower Management Center, you must
use the same registration key and, if necessary, the same NAT ID when you add
this sensor to the Firepower Management Center.
>
Étape 6
Configurez l'interface externe pour l'accès au gestionnaire.
configure network management-data-interface
Vous êtes ensuite invité à configurer les paramètres réseau de base de l'interface externe. Consultez les
informations suivantes pour utiliser cette commande :
• L'interface de gestion ne peut pas utiliser DHCP si vous souhaitez utiliser une interface de données pour
la gestion. Si vous n'avez pas défini l'adresse IP manuellement lors de la configuration initiale, vous
pouvez la définir à l'aide de la commande configure network {ipv4 | ipv6} manual. Si vous n'avez pas
encore défini la passerelle d'interface de gestion sur data-interfaces, cette commande la définit maintenant.
Effectuer la configuration préalable à l'aide de l'interface de ligne de commande
Please stand by.
In most cases, to register
Guide de mise en route de l'appliance Cisco Firepower 1010
63

Publicité

Table des Matières
loading

Table des Matières