SIGNIFY Stonco KEENE AL70 Instructions D'installation

Publicité

Les langues disponibles

Les langues disponibles

Area Light AL70 & AL150
Installation Instructions
WARNINGS
Before starting ensure that the power is disconnected.
All gaskets and hardware used on luminaire must be in place.
Obey all torque requirements to prevent danger of falling
luminaires or falling parts.
PREPARE ELECTRICAL WIRING
Electrical Requirements
• The LED driver must be supplied at 120~277V, 50/60 Hz and
connected to an individual, properly grounded branch circuit
protected by a 20-ampere circuit breaker. Use min 75
Grounding Instructions
• The grounding and bonding of the overall system shall be done in
accordance with NEC Article 600 and local codes.
• When servicing maintain the ground connection between the
luminaire and lid.
1
• Use the Pole Mount Flat Bracket to secure
the thread rods to the pole. The slotted ends
should be facing away from the pole.
• Align with the holes in the pole and thread
through the the Pole Mount Flat Bracket on
the inside of the pole using a flat head
screwdriver.
Figure 1
Pole Mount
Bracket
Bracket
Washers and Nuts
9/22/2020
page 1
www.stonco.com
o
C supply.
2
•Slide the pole mount arm over the
two threaded rods.
• Open the LED driver compartment from the
underside of the fixture.
• Feed the rods through the pole mount
gasket, and secure the fixture to the pole
mount using the spring washers and nuts
inside the compartment. Tighten to 132in-lbs.
Pole Mount Arm
Pole Mount Arm Rods
Driver Compartment Door
www.keene-lighting.com
Site & Area Light
LED Site & Area
AL70 & AL150 Area Light
Tools Required:
#2 Phillips Screwdriver
5/16"-18 Threaded Arm Rods (2x)
Flat Head Screwdriver
Wire Strippers
Wire Cutters
Hex Bit Socket Wrench
or Combo Wrench (1/2")
Pole Mount Flat Back Bracket (1x)
Silicone Caulk
Pole Mount Flat Gasket (2x)
Figure 2
Pole Mount Flat Bracket
Gasket
O-ring
Hardware Supplied:
5/16"-18 Hex Nut (2x)
Lock-Washers (2x)
O-ring (2x)
Fixture Flat Bracket (1x)
3
• Connect the power leads with the
included wire nuts according to the wiring
diagram.
• Close the LED driver compartment door
and secure it with the supplied screws.
Figure 3
Figure 4

Publicité

Table des Matières
loading

Sommaire des Matières pour SIGNIFY Stonco KEENE AL70

  • Page 1 Site & Area Light LED Site & Area AL70 & AL150 Area Light Area Light AL70 & AL150 Installation Instructions WARNINGS • Before starting ensure that the power is disconnected. • All gaskets and hardware used on luminaire must be in place. •...
  • Page 2 AL70 & AL150 LED Area Light Installation Instructions Operation Options Installation Instructions PHOTOCELL OPTION This operation enables the light fixture to automatically turn ON when dark outside and turn OFF when the sun rises. • To enable dusk-to-dawn operation, remove temporary black label cover and ensure the photocell has no cover on it and is unobstructed.
  • Page 3 AL70 & AL150 LED Area Light Installation Instruction Motion Sensor Settings: Note that the motion sensor has a max detection height of 40ft. By default, the motion sensor will be set with the following parameters: • The motion sensor sensitivity is set to 50% •...
  • Page 4 AL70 & AL150 LED Area Light Installation Instruction Dimensions: Pole Arm Mount Slip Fitter Mount 9/22/2020 page 4 www.stonco.com www.keene-lighting.com...
  • Page 5: Luminaire Pour Sites Et Grandes Surfaces

    Luminaire pour sites et grandes surfaces DEL pour sites et grandes surfaces Luminaires pour grandes surfaces AL70 et AL150 Luminaires pour grandes surfaces AL70 et AL150 Directives d’installation AVERTISSEMENTS • Avant de débuter s’assurer que l’alimentation a été coupée • Tous les joints d’étanchéité...
  • Page 6: Dépannage

    AL70 & AL150 Luminaires pour grandes surfaces Directives d'installation Options d'exploitation Directives d'installation Option de cellule photoélectrique Montage en option Cette opération permet au luminaire de s’allumer automatiquement lorsqu’il fait sombre et de s’éteindre lorsque le soleil se lève. • Pour activer l’exploitation du crépuscule à l’aube, retirer temporairement l’étiquette de couverture noire et s’assurer que la cellule photoélectrique ne soit pas recouverte ni obstruée •...
  • Page 7 AL70 & AL150 Luminaires pour grandes surfaces Directives d'installation Réglages du capteur de mouvement: Veuillez noter que le capteur de mouvement offre une détection maximale d’une hauteur de 40 pi. Par défaut le capteur de mouvement sera réglé selon les paramètres suivants: •...
  • Page 8: Dimensions

    AL70 & AL150 Luminaires pour grandes surfaces Directives d'installation Dimensions: Montage sur bras de fût Montage sur raccord lisse 9/22/2020 page 8 www.stonco.com www.keene-lighting.com...

Ce manuel est également adapté pour:

Stonco keene al150

Table des Matières