SIGNIFY Stonco KEENE AL70 Instructions D'installation page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

AL70 & AL150 LED Area Light Installation Instruction
Motion Sensor Settings:
Note that the motion sensor has a max detection height of 40ft.
By default, the motion sensor will be set with the following parameters:
• The motion sensor sensitivity is set to 50%
• When motion is detected by the PIR sensor, the luminaire returns to full power/light output (100%)
• Dimming on low is factory set to 50% with 5 minutes default in "full power" prior to dimming back to low (meaning that it stays
on at 100% after motion for 5 mins).
• When no motion is detected after 5 minutes, the motion response system reduces the wattage by 50%, to 50% of the normal
constant wattage, reducing the light level.
• Other dimming settings can be adjusted manually using the instructions below.
Detection Range Setting (Sensitivity)
Detection range is the term used to describe the radii of the more or less circular detection zone produced on the ground
after mounting the sensor light at a height of 40ft, pull switch to the ON position as "↑", pull switch to the OFF position as
"↓", switch location and detection range of the corresponding table is as follows:
SENSITIVITY: 1, 2
Hold Time Setting
The light can be set to stay ON for any period of time between approximately 10sec and a maximum of 60min. Any
movement detected before this time elapse will re-start the timer. It is recommended to select the shortest time for
adjusting the detection zone and for performing the walk test.
Pull switch to the ON position as "↑", pull switch to the OFF position as "↓", switch location and detection range of the
corresponding table is as follows:
TIME: 3, 4
Light-control Setting
The chosen light response threshold can be infinitely from approximately 10-50 Lux, pull switch to the ON position as
"↑", pull switch to the OFF position as "↓", switch location and light-control of the corresponding table is as follows:
LUX: 5, 6
Stand-by Light Level Setting
Switch to the on is "↑", switch to the off is "↓"; Switch location and Stand-by light level of the corresponding table is
as follows:
STAND-BY LEVEL: 7, 8
Stand-by Time Setting
Switch to the on is "↑", switch to the off is "↓"; Switch location and stand-by time of the corresponding table is as
follows:
STAND-BY TIME: 9, 10
9/22/2020
page 3
www.stonco.com
SENSITIVITY
1 2
20%
50%
75%
100%
TIME
3 4
10S
10 Min
30 Min
60 Min
LIGHT
5 6
(light sensor disable)
10 Lux
30 Lux
50 Lux
STAND-BY LEVEL
7 8
0%
10%
30%
50%
STAND-BY TIME
9 10
+∞
10%
30%
50%
www.keene-lighting.com
Daylight Control Will be Set OFF by default. To turn
it back on, press the
Daylight Sensor Control
• When the light level exceeds this setting, the lights
will turn off even when the space is occupied.
• Once the light level exceeds this setting, the sensor
will wait and monitor for 1min in order to confirm the
light level increase is not temporary before forcing the
lights to go off.
• When the light level goes below the settings, the
light will turn on even without motion detection after
1min. waiting time.
• This feature is disabled by default.
Motion Sensor