Core Post Top PT50
Installation Instructions
WARNINGS
Before starting ensure that the power is disconnected.
This fixture is intended to be mounted on a heavy-duty
pipe or tenon 2 3/8" – 3" outer diameter.
All gaskets and screws used on luminaire must be in place.
PREPARE ELECTRICAL WIRING
Electrical Requirements
• The LED driver must be supplied at 120~347V, 50/60 Hz and
connected to an individual, properly grounded branch circuit
protected by a 20-ampere circuit breaker. Use min 75
Grounding Instructions
• The grounding and bonding of the overall system shall be done in
accordance with NEC Article 600 and local codes.
• When servicing maintain the ground connection between the
luminaire and lid.
1
Pass wires into post top tenon or pipe.
Make wire connections as seen in Figure
1. Place splices and excess wire in tenon
shaft.
Figure 1
11/18/2019
page 1
www.stonco.com
o
C supply.
2
Position fixture on post top tenon or pipe as
seen in Figure 2 below. Be sure not to pinch
wires between the top of the tenon and the
luminaire. Tighten down all eight ¼-20 x ¾"
hex screws provided to 72in-lbs (6ft-lbs).
Figure 2
Wiring compartment with
removable plate
8X ¼-20 x ¾"
hex screw
Pole Top Tenon
2 3/8" O.D. to 3" O.D. x 3" high
www.keene-lighting.com
Site & Area Post Top
LED Post Top
PT50 Core Post Top
Tools Required:
Hardware Supplied
M2.5 Allen Key
¼-20 x ¾" hex screw (8x)
Wire Strippers
#8-32 X 3/8" phillips screw (4x)
Wire Cutters
Phillips Screwdriver
Flathead Screwdriver
3
Restore power at circuit break and switch
on power.
Figure 3
PN 442295136631 Rev C

Publicité

loading

Sommaire des Matières pour SIGNIFY Stonco KEENE PT50

  • Page 1 Site & Area Post Top LED Post Top PT50 Core Post Top Core Post Top PT50 Installation Instructions WARNINGS • Before starting ensure that the power is disconnected. • This fixture is intended to be mounted on a heavy-duty pipe or tenon 2 3/8” – 3” outer diameter. •...
  • Page 2 PT50 LED Post Top Installation Instruction Operation Options Installation Instructions PHOTOCELL OPTION This operation enables the light fixture to automatically turn ON when dark outside and turn OFF when the sun rises. • To enable dusk-to-dawn operation, remove temporary black label cover and ensure the photocell has no cover on it and is unobstructed.
  • Page 3: Dimensions

    PT50 LED Post Top Installation Instruction Dimensions: 11/18/2019 page 3 www.stonco.com www.keene-lighting.com PN 442295136631 Rev C...
  • Page 4: Installation Instructions

    Bout de fût pour sites Site & Area Post Top et grandes surfaces Bout de fût DEL LED Post Top PT50 Core Post Top Bout de fût Core PT50 Directives d’installation Core Post Top PT50 du bout de fût Core PT50 Installation Instructions AVERTISSEMENTS WARNINGS...
  • Page 5 PT50 LED Post Top Installation Instruction PT50 Directives d’installation DEL en bout de fût Operation Options Options d’exploitation Installation Instructions Directives d’installation OPTION DE CELLULE PHOTOÉLECTRIQUE PHOTOCELL OPTION This operation enables the light fixture to automatically turn ON when dark outside and turn OFF when the Cette exploitation permet au luminaire de s’allumer automatiquement lorsque la noirceur s’installe sun rises.
  • Page 6 Dimensions : L’information présentée dans ce document ne constitue pas une offre commerciale et ne fait pas partie d’une soumission ou d’un contrat. © 2019 Signify Holding. Tous droits réservés. Signify ne fait aucune déclaration ni Signify North America Corporation Signify Canada Ltd.