90520983 VPX1301 Cut SAW
WARNING: Fire hazard. Do not store or carry battery so that metal objects can
contact exposed battery terminals. For example, do not place battery in aprons,
pockets, tool boxes, product kit boxes, drawers, etc., with loose nails, screws, keys, etc.
Transporting batteries can possibly cause fires if the battery terminals inadvertently
come in contact with conductive materials such as keys, coins, hand tools and the
like. The US Department of Transportation Hazardous Material Regulations (HMR)
actually prohibit transporting batteries in commerce or on airplanes (i.e., packed in
suitcases and carry-on luggage) UNLESS they are properly protected from short circuits.
So when transporting individual batteries, make sure that the battery terminals are
protected and well insulated from materials that could contact them and cause a short circuit.
STORAGE RECOMMENDATIONS
1. Always store batteries charged.
2. The best storage place is one that is cool and dry away from direct sunlight and
excess heat or cold.
3. Recharge discharged batteries as soon as possible after use or battery life may
be greatly diminished.
CHARGING PROCEDURE
1. Plug the charger into an appropriate outlet before inserting the battery pack.
2. Insert the battery pack into the charger (figure B). Be sure the pack is fully
seated in the charger. While charging, the red (charging) LED will flash continuously
(slowly) indicating that the charging process has started.
3. The completion of charge is indicated by the red LED becoming solid. (approximately
5-6 hours) The pack is fully charged and may be used at this time or left on the charger.
4. Recharge discharged batteries as soon as possible after use or battery life may
be greatly diminished.
CHARGE INDICATORS
Replace Pack:
These chargers are designed to detect certain problems that can arise with battery packs
which would be indicated by the red light flashing at a fast rate. If this occurs, re-insert
battery pack. If problem persists, try a different battery pack to determine if the charger is OK.
If the new pack charges correctly, then the original pack is defective and should be returned
to a service center for recycling. If the new battery pack gives the same trouble indication as
the original, have charger tested at an authorized service center. Note: It may take as long as
fifteen minutes for the charger to determine that the pack is defective.
If the battery pack is too hot or too cold, the LED will alternately blink fast and slow, one flash
at each speed and repeat.
DAISY CHAIN (FIGURE C)
Single and dual port chargers can be electrically connected in any order up to a
maximum of 4 chargers. Each charger has a power-in cord (which plugs into the
electrical outlet) and a power-out cord (which plugs into the next charger).
To connect chargers in a daisy chain:
1. Plug the power-in cord into an electrical outlet.
2. Remove the power-in cord from the next charger and plug in the power-out cord from
the charger that is now plugged into the outlet.
3. Repeat this process for the remaining chargers.
Chargers that are daisy chained together operate independently as though each one was
plugged into a sperate outlet therefore a battery can be removed from anywhere along
the daisy chain without affecting the other chargers.
LEAVING THE BATTERY IN THE CHARGER
The charger and battery pack can be left connected indefinitely with the LED illuminated. You
may see the LED return to flashing (charging) state, as the charger will occasionally "top off "
the battery charge.
7/19/07
3:03 PM
Page 8