Prepare built-in units
Important: The power outlet must be located outside the
built-in cut-out.
Make sure there is adequate air circulation. To do this, remove
the rear panel of the cabinet or cut out an opening of 19
15
/
" (500 x 400 mm). There must be a gap of at least 1
3
4
(35 mm) between the wall and base of the unit or the rear panel
of the unit situated above. The ventilation slots and intake open-
ings must not be covered. Also follow the installation instruc-
tions for the appliance situated above or below. If installing the
appliance above a warming drawer, the height of the recess
must be 23
/
" (590 mm). If the appliance is installed directly
1
4
under a décor panel, ensure that there is a ventilation slot of at
least 31 square inches (200 cm
The appliance should not be installed too high (approx. 37
950 mm) to ensure that function parts, e.g. container or brewing
unit, can be removed without difficulty. The display should not
be located above eye level to ensure legibility.
Protect your Coffeemaker and hoses against freezing or it will
be damaged.
¡
CAUTION
Installation must always be performed by 2 persons.
Installation preparation
1 Unpack all the parts and check for any damage in transit.
Do not operate a damaged appliance.
2 Take note of the installation dimensions of the particular
model.
Important: Two opening angles can be selected for the door.
Depending on the opening angle required, the mounting
distance to the wall should be observed before installation.
● Opening angle approx. 110° (delivery status)
= mounting distance to the wall at least 13
● Opening angle approx. 155°
= mounting distance to the wall at least 25
For an opening angle of 155°, remove both the restrictors at the
top and bottom of the hinge.
3 Remove the installation template on the back of the
installation instructions. Place the installation template at the
front edge of the unit and screw on the assembly bracket c
as shown with two fastening screws f. The assembly
bracket must be positioned at the base of the unit and the
wall such that no gap is present.
4 Fasten the the transformer mount d with two screws f in
the middle.
5 Insert the transformer in the mount. The connections to both
lines must point to the left.
Note: When positioning the transformer k and pushing in the
appliance, do not trap the lines.
The transformer k is not allowed to touch the appliance and
the back wall of the cupboard.
6 Set the mains switch U to h on the appliance.
7 Important:
● The distance between the appliance and the rear wall
must be at least 3
/
15
● A recess of 423/32" (120 mm) x 1113/16" (300 mm) is
required for water inlet hose and drain water hose. If
required, adjust the furniture base accordingly.
● The hose guide l should end at the edge of the furni-
ture base. The hose guide l should be adapted to the
edge of the furniture if necessary.
).
2
/
" (350 mm).
3
4
/
" (650 mm).
9
16
" (100 mm).
16
8 Screw the hose guide l with the fastening screw i to the
rear wall of the appliance. Insert the drain water hose in the
hose guide l. Place the hose straight on the bottom of the
furniture and run down over the edge. Feed the water inlet
hose and the drain water hose through the cabinet to the
back.
/
" x
11
16
/
"
3
NOTICE:
8
The connecting cable and hoses must not be kinked, crushed
or twisted.
Water connection
● Before connecting the appliance, turn on the tap on the water
connection and draw off approx. 340 fl. oz. (10 l) of water to
clean the domestic water pipe. Then turn off the tap.
¡
/
" /
7
WARNING
16
Risk of electric shock
– The appliance must be disconnected from the electrical
supply.
– Only connect the appliance to the cold water connection.
– Check that the water inlet hose is not kinked, crushed or
twisted.
– The plastic housing in the AquaStop contains an electric
valve so do not immerse in water.
– The water inlet hose contains the connecting lines so do not
cut through this hose (Fig. 10).
– Screw the water inlet hose with the AquaStop to the tap.
– Slowly turn on the tap so it is fully open.
– Check the connections and water inlet hose for leaks.
Drainage connection
¡
CAUTION
– The domestic drain water system must be vented. Ensure
venting, e.g. through connection to a sink or via a funnel
siphon.
– The siphon must have a suitable connection.
– The waste water hose must not be higher than the lower
edge of appliance at any point.
– Check that the drain water hose is not kinked, crushed or
twisted.
– Check that there is not a cover in the drain water
connection preventing drainage of the water. Remove if
necessary.
9 Position the hose with a continuous slope to avoid a
bend (I). Shorten the hose if necessary (II).
10 Place the hose clamp for the adapter and the adapter on the
waste water hose and screw the hose clamp tight (I-IV).
11 Remove the cap from the adapter (I).
Place the hose clamp on the adapter (II).
Slide the adapter onto the waste water connection or hang
into a funnel siphon. When connecting to a waste water
connection, use the hose clamp to secure the adapter
(III-IV).
Important: Check the connections and waste water connection
for leaks.
12 Check the water drainage. To do so, slowly pour approx.
17 fl. oz. (0.5 l) water from a container, e.g. jug, into the drip
tray. The water must drain off completely. If the water fails to
drain off, check installation of the hose and the drain water
connection according to the information in these installation
instructions.
en –
11