If the device is powered by a generator or transformer, the generator or transformer's power output must be
at least twice the rated input power shown on the rating plate of the device. The operating voltage of the
transformer or generator must always be within +5 % and -15 % of the rated voltage of the device.
Weight in accordance with EPTA procedure 01
Revolutions per minute (stage 1)
Revolutions per minute (stage 2)
Revolutions per minute (stage 3)
Revolutions per minute (stage 4)
Revolutions per minute (stage 5)
Rated speed under no load
Disc diameter
Disc thickness
4.1
Noise information and vibration values in accordance with EN 62841
The sound pressure and vibration values given in these instructions were measured in accordance with a
standardized test and can be used to compare one power tool with another. They can also be used for a
preliminary assessment of exposure.
The data given represent the main applications of the power tool. However, if the power tool is used for
different applications, with different accessory tools, or is poorly maintained, the data can vary. This can
significantly increase exposure over the total working period.
An accurate estimation of exposure should also take into account the times when the tool is switched off, or
when it is running but not actually being used for a job. This can significantly reduce exposure over the total
working period.
Identify additional safety measures to protect the operator from the effects of noise and/or vibration, for
example: maintaining the power tool and accessory tools, keeping the hands warm, organization of work
patterns.
Noise information
Sound power level (L
WA
Uncertainty for the sound power level (K
Emission sound pressure level (L
Uncertainty for the sound pressure level (K
Vibration information
Vibration emission value for grinding concrete (a
Vibration emission value for surface grinding (a
Uncertainty (K)
5
Preparations at the workplace
CAUTION
Risk of injury! Inadvertent starting of the product.
▶ Unplug the supply cord before making adjustments to the power tool or before changing accessories.
Observe the safety instructions and warnings in this documentation and on the product.
5.1
Installing an accessory tool
CAUTION
Risk of damage and risk of injury due to damaged Keyless quick-action clamping screw. The Keyless
quick-action clamping screw can snap off if it is overtightened.
▶ Never use a tool to tighten the Keyless quick-action clamping screw. Tighten it by hand only.
1. Clean the chuck.
2. Slip the mounting flange on to the arbor and turn the mounting flange until it engages.
20
English
)
)
WA
)
pA
)
pA
102 dB(A)
3 dB(A)
91 dB(A)
3 dB(A)
)
10.5 m/s²
h, CG
)
5.6 m/s²
h, AG
1.5 m/s²
2240961
5.6 kg
3,300 /min
4,125 /min
4,950 /min
5,775 /min
6,600 /min
7,000 /min
150 mm
4 mm ... 4.5 mm
*2240961*