5. VENTING METHODS
•
This range hood is factory set for venting through the roof or wall. It is not intended for use in
non-vented/re-circulating)
•
Vent work can terminate either through the roof or wall. To vent through a wall, a 90° elbow is needed.
• NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or
garages. All exhaust must be ducted to the outside.
• Use metal/aluminum duct work only.
• Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape.
• Use caulking to seal exterior wall or roof opening around the cap.
Horizontal Wall Venting
7
Side
Wall
Cap
WARNING
Vertical Roof Venting
Roof cap