Pentair Hoffman DAH1001A Mode D'emploi page 3

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
LOCATION AND MOUNTING
1. Hoffman electric heaters should be centered as
low as possible in the enclosure for optimum heat
distribution.
2. It is recommended that the heater be installed
on a panel for optimum performance. It may,
however, be mounted on any metal surface.
3. The heater should be mounted in a vertical
position with the terminal block at the bottom and
the air outlet openings at the top as shown.
4. Heaters should not be installed on wood or
other combustible surfaces.
5. Heat sensitive components should not be
placed above the heater discharge area.
6. The recommended clearances shown by the
shadowed area indicate the space that should be
kept free of components for safe operation of the
heater.
7. Four 10−32 UNF, self−tapping screws are
included for installation.
Thermal sensitive devices or materials may need to be
located further from the heater than the minimum
recommended distance.
DAH1001A DAH1002A
DAH2001A DAH2002A
DAH4001B DAH4002B
DAH8001B DAH80002B
60
108
50
90
40
72
30
54
20
36
10
18
0
0
2
50mm
Vertical Distance Above Heater, inches/mm
Temperature measurements reflect unrestricted air flow.
87565511
CAUTION
Watts
X
100
4
200
6
400
6
800
8
Temperature Rise Vs Distance Above Heater
4
6
102mm
152mm
E 2005 Hoffman Enclosures Inc.
D
E
5.00
5.00
3.25
3.25
127 mm
83 mm
7.00
7.00
3.50
3.50
178 mm
89 mm
X
8
10
203mm
254mm
Vertical Surface Mounting
Optional Horizontal
Surface Mounting
12
559mm
X (Minimum
recommended
distance above
heater)
100 Watt Heater
200 Watt Heater
400 Watt Heater
800 Watt Heater
3

Publicité

Table des Matières
loading

Table des Matières