Table 7 High fault short circuit ratings, using Bul. 140MG, circuit protector, per UL508 and CSA 22.2 No.14
E1 Plus Cat. No.
ED1ED, ED1FD,
EEED, EEFD, EEQD
193
EEEE, EEFE,
EEGE, EEVE
Table 8 High fault short circuit ratings, using Bul. 140G-H frame, circuit breakers, per UL508 and CSA 22.2 No.14
E1 Plus Cat. No.
ED1ED, ED1FD,
EEED, EEFD, EEQD
193
EEEE, EEFE,
EEGE, EEVE
Table 9 Group installation short circuit ratings
Catalog Nos. 193/592-EE and ED1 noted below have the following group installation
short circuit ratings when used with the specified contactors and branch circuit
protection.
Overload Relay
-ED1AB, -ED1BB,
-ED1CB, -ED1DB,
-ED1EB.
193
-EEAB, -EEBB, -EECB,
-EEDB, -EEEB.
-ED1AB, -ED1BB,
-ED1CB, -ED1DB,
-ED1EB.
193
-EEAB, -EEBB, -EECB,
-EEDB, -EEEB.
E
K
CONTACTOR CAT. NO.
100-C09, -C12,
-C16, -C23
100-C30, -C37
100-C43, -C55
100-C60, -C72, -C85, -C97
300-AO_, -BO_
300-CO_
Publication 193-IN039M-MU-E - September 2015
Contactor Cat.
Max. starter
No.
FLC (A)
100-C30
30
100-C37
37
100-C43
43
100-C60
60
100-C72
72
100-C85
85
100-C97
97
Contactor Cat.
Max. starter
No.
FLC (A)
100-C30
30
100-C37
37
100-C43
43
100-C60
60
100-C72
72
100-C85
85
100-C97
97
Max. Available
Contactor
Fault Current
100 -C09,
100 -C12,
5,000
100 -C16
100 -C09,
100 -C12,
30,000
100 -C16
A
F
G
D
E1 PLUS CAT. NO.
mm
193-ED1_B, 193*-EE_B
(in)
mm
(in)
193-ED1_D,
193*-EE_D
mm
(in)
mm
193*-EE_E
(in)
mm
193-ED1_D,
(in)
193*-EE_D
mm
193*-EE_E
(in)
Max. available fault current (kA)
At 480V
At 600V
65
25
65
25
65
25
65
25
65
25
65
25
65
25
Max. available fault current (kA)
At 480V
At 600V
50
25
50
25
50
25
65
25
65
25
65
25
65
25
Table 10 Short circuit ratings, using 140U D Frame circuit breakers,
per UL508 and CSA 22.2
Overload Relay
Max.
UL Fuse
Voltage
193
Class RK5
480
60 Amp.
193
Class J
480
100 Amp
193
B
A
B
C
45
146.6
85.2
(1.76)
(5.77)
(3.35)
45
101.2
146.6
(1.76)
(5.77)
(3.98)
54
101.2
146.6
(2.12)
(5.77)
(3.98)
72
192
120.4
(2.83)
(7.57)
(4.74)
45
101.2
146.6
(1.76)
(5.77)
(3.98)
72
192
120.4
(2.83)
(7.57)
(4.74)
Circuit Protector Cat.
Max. Circuit Protector
No.
Current (A)
140MG-H8P-C50
140MG-H8P-C50
140MG-H8P-C50
140MG-H8P-D12
140MG-H8P-D12
140MG-H8P-D12
140MG-H8P-D12
Circuit Breaker Cat.
Max. Circuit Breaker
No.
Current (A)
140G-H6C3-C50
140G-H6C3-C50
140G-H6C3-C50
140G-H6F3-D11
140G-H6F3-D11
140G-H6F3-D11
140G-H6F3-D12
Contactor
-ED1AB, -ED1BB,
100-C09,
-ED1CB, -ED1DB,
100-C12,
-ED1EB.
100-C16
-EEAB, -EEBB, -EECB,
100-C23
-EEDB, -EEEB.
-ED1AB, -ED1BB,
100-C09,
-ED1CB, -ED1DB,
100-C12,
-ED1EB.
100-C16
-EEAB, -EEBB, -EECB,
100-C23
-EEDB, -EEEB.
-ED1AB, -ED1BB,
100-C09,
-ED1CB, -ED1DB,
-ED1EB.
100-C12,
100-C16
-EEAB, -EEBB, -EECB,
-EEDB, -EEEB.
100-C23
H
J
C
D
E
F
G
24.5
13.9
35
60
(.96)
(.55)
(1.38)
(2.36)
24.5
13.9
35
60
(.96)
(.55)
(1.38)
(2.36)
18.4
45
60
24.5
(.96)
(.74)
(1.77)
(2.36)
23.8
29
55
100
(.94)
(1.14)
(2.16)
(3.94)
13.9
35
60
24.5
(.96)
(.55)
(1.38)
(2.36)
29
23.8
55
100
(.94)
(1.14)
(2.16)
(3.94)
Copyright © 2015 Rockwell Automation, Inc. All Rights Reserved. Printed in USA.
Minimum Enclosure
Size (in.)
50
50
24x20x8
50
with two hinges
125
and two multi-turn
125
screw type latches
125
125
50
50
50
110
110
110
125
Circuit Breaker
Short Circuit
Catalog Nos.
Rating
140U-D6D3-A50,
-B10, -B20, -B30,
65,000 A.
-B40, -B50, -B60
480Y / 277 VAC
-B80, -C10, -C12,
-C15, -C20, -C25,
-C30
140U-D6D3-A50,
-B10, -B20, -B30,
5,000 A.
-B40, -B50, -B60
600Y / 347 VAC
-B80, -C10, -C12,
-C15, -C20, -C25,
-C30
140U-D6D3-A50,
-B10, -B20, -B30,
35,000 A.
-B40, -B50, -B60
600Y / 347 VAC
-B80, -C10, -C12,
-C15, -C20, -C25,
-C30
H
J
K
86.5
2
4.5
(3.40)
(.08)
(.17)
104
2
4.5
(4.09)
(.08)
(.17)
104
2
4.5
(4.09)
(.08)
(.17)
5.4
126
2
(4.94)
(.08)
(.21)
104
2
4.5
(4.09)
(.08)
(.17)
5.4
126
2
(.21)
(4.94)
(.08)
41053-358-01
DIR 41053-358 (Version 13)