1 Ambient, no heat - PAEC3200 A (IP44)
Item
Type
number
77517
PAEC3210A
PAEC3215A
77518
77519
PAEC3220A
*
) Sound power (L
) measurements according to ISO 27327-2: 2014, Installation type E.
1
WA
*
) Sound pressure (L
2
pA
absorption area: 200 m². At 50% and 100% airflow.
*
) Applicable at 50% and 100% airflow.
3
Output
Airflow
Sound
power*
[kW]
[m
/h]
[dB(A)]
3
0
1950
74
0
2700
74
0
3800
77
). Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent
PAEC3200
Sound
Voltage
pressure*
motor
1
2
[dB(A)]
[V]
40/58
230V~
39/58
230V~
43/61
230V~
Amperage
Length
Weight
motor*
3
[A]
[mm]
[kg]
0,19/1,15
1068
22
0,20/1,20
1578
32
0,36/2,30
2068
42
9